Technical data
14. Select Save changes to NVRAM.
Identify the EFI path of the physical hardware path on systems that have Secure Path installed.
Determining th
e active or standby path’s hardware path
To determine th
e hardware path of a standby path by using the spmgr display and ioscan
commands, see “Installing Secure Path on a SAN boot d evice” in the HP StorageWorks Secure Path 3.0F
Service Pack 3 for H P-UX 11i v1.0 a nd 11i v2.0 installation and reference g uide.
To determine the ha rdware path of a standby path:
1. Enter the spmgr display -dv boot device command on the host. In this example, the
boot device is
/dev/dsk/c12t1d2.
spmgr display -dv c12t1d2
The following output is displayed:
Server:aphn1
.india.hp.comReport Created: Fri, Jan 30 18:44:42 2004
Command: spmgr display -dvc12t1d2
Device:c12t1d2 Status:Operational[4 paths (1/0/2)] Storage:
5000-1FE1-00
15-0AE0 LUNID: 6005-08B4-0001-4920-0001-6000-04EA-0000
Preferred Controller: None HBAs:td4td6
Item Device Controller HBA H/W_Path Instance
============
==================
0 c12t1d2 P4889B49IM403L td4 255/255/0/2.3 c4t1d3 WWPN: N/A Path
State: Active
1 c12t1d2 P488
9B49IM403L td6 255/255/0/2.3 c8t1d3 WWPN: N/A Path
State: Available
2 c12t1d2 P4889B49IM403A td4 255/255/0/2.3 c6t1d3 WWPN: N/A Path
State: Standb
y
3 c12t1d2 P4889B49IM403A td6 255/255/0/2.3 c10t1d3 WWPN: N/A Path
State: Standby
Theoutputsho
ws four operation paths: one is in Active path state, one is in Available path state,
and two are in Standby path state. Select one of the path instances to determine the hardware
path (for example, c6t1d3). Note the values c(6), t(1),andd(3) in the instance.
2. Enter the ios
can -kfnC ext_bus command. O utput similar to the following is displayed:
# ioscan -kfnC ext_bus
Class I H/W Path Driver S/W State H/W Type Description
============
==================
ext_bus 0 0/0/1/0 c720 1 CLAIMED INTERFACE SCSI C896 Ultra Wide
Single-Ended
ext_bus 1 0/0/
1/1 c720 CLAIMED INTERFACE SCSI C896 Ultra Wide
Single-Ended
ext_bus 2 0/0/1/1 c720 CLAIMED INTERFACE SCSI C87x Ultra Wide
Single-Ended
ext_bus 3 0/0/1/1 c720 CLAIMED INTERFACE SCSI C87x Ultra Wide
Single-Ended
ext_bus 4 0/3/
0/0.1.10.0.0 fcparray CLAIMED INTERFACE FCP Array
Interface
ext_bus 6 0/3/0/0.1.11.0.0 fcparray CLAIMED INTERFACE FCP Array
Interface
ext_bus 12 255/255/0 swsp CLAIMED VIRTBUS HSV110 (C)COMPAQ
0x50001FE1500049B0
Use the second
(instance) and third (H/W pa th) fields of the output to determine the hardware
path. Find the ext_bus device that has the same instance number as the value of c in
step 1.Inthisexample,itisext_bus 6.
ext_bus 6 0/3/
0/0.1.11.0.0 fcparray CLAIMED INTERFACE FCP Array
Interface
3. Append the t and d values fr om (step 1t(1), d(3)) to the hardware path determined in step 2
to determine
the hardware path of the standby path. In this example, the h a rdware path for
the standby path is c6t1d3 is 0/3/0/0.1.11.0.0.1.3.
HPStorageWorksSecurePath3.0FServicePack3forHP-UX11iv1.0and11iv2.0
11