Metric Rackmount Procedure:
1.
Reference Figure B-4
,
Metric Rackmount Installation Layout
. Mount the
appropriate metric conversion bracket to both ends of the slide using the 10-
32 nuts provided in the slide kit. Do this for both the left and right slide
assembly. For modules 1 and 2, use P/N 968313-101. For modules 3 and 4,
use P/N 968320-101. Make sure that these brackets are oriented so that the
numbers are right side up in all corners.
2. Mounting the bracket/slide assembly to the StorageWorks:
I. If installing the first module, select a mounting location.
a) Mount each slide/bracket assembly to the rack by aligning the two
mounting holes marked #1 to holes on the rack. Start by mounting
the slide/bracket assembly to the
rear
of the StorageWorks first.
Hold the bracket/slide assembly in place with one hand, fasten a
mounting screw to the holes marked #1.
b) To mount the front bracket, place bracket (P/N 968312-101)
in
front
of the rack with the holes marked #1 aligned to the holes on
the rack.
c) Extend the slide/bracket assembly forward to mate with the rack.
Align the holes marked #1 on the slide/bracket assembly with the
hole #1 on the front bracket and fasten two mounting screws
through the two #1 holes.
d) Be careful to mount all four brackets at the same height. You can
use a ruler or count holes to achieve this.
e) Tighten all four corners and the slide extension.
I. Procedure for installing modules 2, 3, or 4:
b) Each unit is 7 inches high. To locate the mounting location of the
next bracket/slide assembly, use a ruler to measure 7 inches vertical
distance of the protruding stud from the bracket above to the stud of
the bracket which is to be installed. The mounting holes marked for
the number of the module being installed should automatically line
up with the rack holes.