User`s guide
DLT MiniLibrary (TL891) - User’s Guide
4–10 EK–TL891–UG. A01
4.2.6 Set Time
Enables you to set the module’s clock.
4.2.7 Set Baud Rate
Enables you to set the data transmission rate of the module’s trace port. This
function is intended for use by CEs only. The default is 38400 bits/sec.
4.2.8 Set Serial Number
This option enables you to alter the Base Module’s serial number as stored in the
unit. The Base Module’s robotics reports these settings in response to the SCSI
Inquiry command, in the Unit Serial Number Page.
4.2.9 Set Unload Mode
This option determines whether a SCSI Move Medium command is interpreted as
implicit or explicit. If implicit, when the module receives a SCSI Move Medium
command for a fetch from a drive, it unloads the drive before attempting to fetch
a cartridge from that drive. If explicit, the host must issue a SCSI Unload
command before each Move Medium command where the source element is a
drive. The default is Implicit.
4.2.10 Set Negotiation
This option allows the Base Module to initiate negotiations for synchronous data
transfer and wide data transfer from the host. Only models with a fast/wide drive
installed can initiate a ‘wide’ negotiation. The default is Do Not Initiate.
4.2.11 Set Special Configuration
This option contains predefined Digital operational configurations. Refer to the
“
Special Configuration Options’
section within Table 4-1 for default
configuration characteristics
4.2.12 Set Default
This option resets all of the preceding configuration options to their factory
defaults, excepting Date and Time, which remain at their current settings.