User`s guide
Chapter 4. Configuration
EK–TL891–UG. A01 4–7
5.
To set the TUR Reporting option
- press the
Escape
key to move up one
level to the Configure Submenu (Figure 4-9) and use the
arrow to move
the
to
Set Special Config (11
th
menu item from top) and press
Enter
.
Figure 4-9 Configure Submenu
The front panel will display the Special Config Submenu (Figure 4-10).
Figure 4-10 Special Config Submenu
Press twice to position the next to the TUR Reporting option. Press
Enter
to move down one line to *Standard. Use the to change to
Custom and press
Enter
to accept this setting. To return the module to online
status, press
Escape
three times.
4.2.4 Set Element Base
This option allows you to set the base addresses of each of the three SCSI
elements of the module. In order to identify sources and destinations in
commands to the robotics, the base module is divided into elements, each of
which is assigned a separate designator or element address. The Transport
Element is the robotics mechanism itself; the Storage Elements are the 10 slots in
the magazine; the Transfer Elements are the drives. The Base Module reports
these settings in response to the SCSI Mode Sense command, in the Element
Address Assignment Page. The defaults are Transport = 0000h; Storage element
base = 0001h, Transfer element base = 00F0h.
Set Data Format
Set SCSI
Set Library Mode
Set Element Base
Mode Pg 1F Length
* Short (0x0E)
Model Number
* Digital TL89X