User`s guide
Troubleshooting 103
Troubleshooting
4  After the device files have been created, issue the FCMSUTIL command on 
the device files. For example:
/opt/fcms/bin/fcmsutil /dev/fcms0
The output should appear similar to the following:
 Local N_Port_ID is = 0x000001
 N_Port Node World Wide Name = 0x10000060B03E22CB
 N_Port World Wide Name = 0x10000060B03E22CB
 Topology = IN_LOOP
 Speed = 1062500000 (bps)
 HPA of card = 0xFBF48000
 EIM of card = 0xFFFA000A
 Driver state = Ready
 Number of EDB’s in use = 0
 Number of OIB’s in use = 0
Number of Active Outbound Exchanges = 1
 Number of Active Login Sessions = 5
A driver state of Ready indicates that the driver is in the correct operating 
state. IN_LOOP topology indicates that the host has detected an FC-AL.
5  Check Fibre Channel cables for loose connections.
6  Check the Enclosure ID switches for conflicting loop IDs. Make sure both 
LCCs have the same ID setting.