Technical data

66 HP Surestore FC Switch 6164 Installation and Reference Guide
Note
If the domain ID (whether the default or a selected ID) is already
in use when the switch is connected to the fabric, it is automatically
reset to a unique value. You can determine which domain IDs are in use
by issuing the Telnet command
fabricShow
on one of the switches in
the integrated fabric.
a. Disable the switch by entering the following:
switchDisable
b. Enter the following:
configure
c. Enter “Y” after the “
Fabric parameters
” prompt.
Fabric parameters (yes, y, no, n): [no] y
d. Enter a unique domain ID (such as the domain ID used by the previous
switch, if still available).
Domain: (1..239) [1] 3
e. Complete the remaining prompts (or press Ctrl+D to accept the
defaults without completing the prompts).
f. Re-enable the switch by entering the following:
switchEnable
15.Download the switch configuration, if one was uploaded from the
previous switch (see Step 2).
a. Disable the switch by entering the following:
switchDisable
b. Enter the following at the Telnet prompt to download the configuration
from the server to the switch:
configDownload
Several prompts display to gather information about the file being
downloaded.