Technical data

64 HP Surestore FC Switch 6164 Installation and Reference Guide
10.Connect the following:
power cable to the power connector
serial cable to the serial port (if used)
Ethernet cable to the Ethernet port
Note
Do not connect the ISL (interswitch link) or user fiber optic
cables until after the switch is configured.
Configuring the New Switch
Note
The switch can be accessed simultaneously from multiple
connections; ensure that the system is not modified from more than one
connection during the following procedure.
11. Replace the factory IP address and related information with the address
information used by the previous switch.
a. Connect the new switch to a workstation by serial cable.
b. Open and configure a terminal emulator application (such as
HyperTerminal) as follows:
c. From the terminal emulator application, log on to the new switch
through the serial connection.
Parameter Value
Bits per second: 9600
Databits: 8
Parity: None
Stop bits: 1
Flow control: None
Function arrows and Ctrl keys act as: Terminal keys
Emulation: Autodetect