Technical data

60 HP Surestore FC Switch 6164 Installation and Reference Guide
b. Enter
sgroupShow
at the Telnet prompt to display group information.
This command lists the WWNs for each switch in the FC 6164,
beginning with switch 1 (the switch on the far left).
Example
reg101:admin> sgroupShow
Group Type Group Name Member WWN
==============================================
S64_6_1 East Lab 10:00:00:60:60:10:60:11
10:00:00:60:60:10:60:22
10:00:00:60:60:10:60:33
10:00:00:60:60:10:60:44
10:00:00:60:60:10:60:55
10:00:00:60:60:10:60:66
Note
The
fabricShow
command provides information about all the
switches in the larger SAN fabric. For details about the
fabricShow
command, refer to the Fabric OS v2.2 manual.
c. Record the WWNs, domain IDs, IP addresses, and other relevant
information for all switches in the group on the FC 6164 worksheet
(provided in Appendix A, “FC 6164 Worksheet”).
Note
Keep the completed worksheet readily available for future work
on the FC 6164. However, do not tape the worksheet to the front door or
rear panel, to prevent disruption of airflow through the chassis.
2. If the faulty switch is partly or fully operational, back up the current
configuration.