Technical data
54 HP Surestore FC Switch 6164 Installation and Reference Guide
d. Enter “Y” after the “
Fabric parameters
” prompt.
Fabric parameters (yes, y, no, n): [no] y
e. Enter a unique domain ID (such as the domain ID used by the previous
switch, if still available).
Domain: (1..239) [1] 3
f. Complete the remaining prompts (or press CTRL+D to accept the
remaining settings
without completing all the prompts).
g. Re-enable the switch by entering the following:
switchEnable
h. Repeat Steps a through g for the remaining switches.
5. Specify the desired status policies for your fabric.
a. Log on to the first switch by Telnet.
b. Enter the following at the prompt:
switchStatusPolicySet
c. Specify the desired status policies. To completely deactivate the alarm
for a particular condition, enter “0” at the prompt for that condition.
d. Repeat Steps a through c for the remaining five switches in FC 6164.
6. Check the FC 6164 for port or ISL issues.
a. Log on with administrative privileges by Telnet to one of the switches
in the integrated fabric.
b. Enter the following at the Telnet prompt:
islTopoShow
This command provides general information about all the switches in
the FC 6164. Any problems are indicated by an error condition in the
Status column.