Technical data
Installing and Configuring the FC 6164 45
WARNING
The FC 6164 weighs approximately 200 pounds.Two or
more people are required when positioning the switch in the rack. Move
the switch chassis slowly and carefully at all times, and continue
supporting it until it is correctly positioned on the rail tray and fastened
to the rack. Use extreme caution when handling or transporting the
switch to prevent injury to personnel, damage to the switch, and/or
damage to the rack and other equipment mounted in it.
f. Put flat washers on four ΒΌ-20 screws with captive lock washers, and
insert the screws through the holes in the rack uprights and into the
threaded holes in the flanges of the rack-mount bracket adjustable
plates (see Figure 16). Do not tighten the screws at this time.
13.From the back of the rack, insert four #10-32 x 5/8-inch Phillips pan-head
screws with captive lock washers through the holes in the rack-mount
flanges attached to the front end of the switch and into the Tinnerman nuts
you placed in the rack in Step 5 (see Figure 10 and Figure 17). Tighten
the screws fully.
Note
For an HP rack, you may have to adjust the positions of the
Tinnerman nuts to get them to align properly with the holes in the rack
uprights. If necessary, use a screwdriver blade inserted through the holes
in the rack uprights to reposition the Tinnerman nuts.