Technical data
206 HP Surestore FC Switch 6164 Installation and Reference Guide
Temperatures 2 1
Fans 2 1
PortStatus 0 0
sgroup ISLStatus 2 1
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
The minimum number of
FaultyPorts contributing to DOWN status: (0..8) [2]
FaultyPorts contributing to MARGINAL status: (0..8) [1]
MissingGBICs contributing to DOWN status: (0..8) [0]
MissingGBICs contributing to MARGINAL status: (0..8) [0] 1
Bad PowerSupplies contributing to DOWN status: (0..2) [2]
Bad PowerSupplies contributing to MARGINAL status: (0..2) [1]
Bad Temperatures contributing to DOWN status: (0..5) [2]
Bad Temperatures contributing to MARGINAL status: (0..5) [1]
Bad Fans contributing to DOWN status: (0..6) [2]
Bad Fans contributing to MARGINAL status: (0..6) [1]
Down PortStatus contributing to DOWN status: (0..8) [0]
Down PortStatus contributing to MARGINAL status: (0..8) [0]
Down ISLStatus contributing to DOWN status: (0..16) [2]
Down ISLStatus contributing to MARGINAL status: (0..16) [1]
Policy parameter set has been changed
... Committing configuration...done.