Technical data

154 HP Surestore FC Switch 6164 Installation and Reference Guide
Configure Thresholds tab always contains Default, Apply and Reset
buttons:
Thresholds for the Environmental and GBIC Classes
The Environmental and GBIC classes both display a separate column for
each area (see
Figure 38).
Default Click to return settings to default values.
Apply Click to apply the values specified in the
current display. When Apply is clicked after a
change, the Alarm Mechanism dialog
displays:
To continue, select the type of alarm you want
and click Apply.
Reset Click to undo the last changes that were
applied.
The columns for the Temperature, Fan, RX Power, and TX Power areas
contain the following items:
Threshold Type
drop-down list
Select the threshold type (outranged, above,
in-between, below, changed).
High/Low
drop-down list
Select to enter the high and low settings for the
threshold type selected in the Threshold Type
drop-down list (not available for all areas).
Scale Specify the point at which you want to set the
specified threshold.
Area drop-down
list
Select a Fabric Watch area.