Technical data
140 HP Surestore FC Switch 6164 Installation and Reference Guide
Mcast Frames Transmitted Number of multicast frames transmitted.
Time R_RDY Priority Number of times R_RDY has priority over
frames to be sent.
Time BB_Credit Zero Number of times BB_Credit went to zero.
Encd Errs Inside Frames Number of encoding errors inside frames.
Frames with CRC Errs Number of frames with CRC errors.
Short Frames Number of frames shorter than minimum.
Long Frames Number of frames longer than maximum.
Bad End-of-Frames Number of frames with faulty end-of-frames.
Encd Errs Outside Frames Number of frames with encoding errors
outside frames.
C3 Frames Discarded Number of class 3 frames discarded.
LIP Ins Number of LIPs received.
LIP Outs Number of times loop initialized by FL_Port.
Last LIP Received Last LIP received: AL_PD, AL_PS.
Frames Rejected Number of F_RJTs sent.
Frames Busied Number of F_BSYs sent.
Link Failure Number of times NOS received/sent.
Loss of Sync Number of times loss of sync occurred.
Loss of Signal Number of times loss of signal occurred.