Technical data

116 HP Surestore FC Switch 6164 Installation and Reference Guide
The following fields are included in the Name Server Table:
The Name Server Table also includes the following columns:
Auto Refresh Check to enable Auto Refresh or uncheck to disable.
Auto Refresh
Interval
If Auto Refresh is checked, enter the number of
seconds for the refresh interval.
Refresh Click to refresh the window immediately.
Done Click to close the window.
Domain # The domain ID of the switch to which the device is
connected.
Port # The number of the switch port to which the device is
connected.
Port ID The port ID of the device (24-bit hexadecimal value).
Port Type The port type of the device (N for fabric direct
attached port, or NL for fabric direct attached loop
port).
Port WWN The worldwide name of the device port.
Node WWN The worldwide name of the device node.
Symbolic Name The symbolic name of the device assigned through the
SCSI INQUIRY command.
FC4 Types The fibre channel FC4 layer types supported by the
device, such as IP or FCP.
COS The fibre channel classes of service supported by the
device.
Fabric Port Name The name of the fabric port in use by the device.
Port IP Address The IP address of the fabric port.