HP2-T26 Passing Score: 800 Time Limit: 120 min HP HP2-T26 - Servicing HP BladeSystem Solutions Exam
HP2-T26 Servicing HP BladeSystem Solutions QUESTION 1 How does a c7000 enclosure retain air handling integrity when a server blade is removed? A. B. C. D.
B. BL870c C. BL685 G7 D. BL490 G6 Correct Answer: B Section: (none) Explanation Explanation/Reference: The Integrity BL870c i2 serverblade is a full-height, double-wide form factor server blade that occupies two device bay slots in a BladeSystem enclosure. QUESTION 5 Technician is installing HP ProLiant servers at different customer sites. Since the technician wants to have the ProLiant equipped with the latest firmware level available, what is the best solution? A.
HP ProCurve 6120XG Blade Switch (516733-B21) HP ProCurve 6120G/XG Blade Switch (498358-B21) Cisco Catalyst Blade Switch 3120G for HP (451438-B21) Cisco Catalyst Blade Switch 3120X for HP (451439-B21) Cisco Catalyst 3020 Blade Switch (410916-B21) HP GbE2c Layer 2/3 Ethernet Blade Switch (438030-B21) HP 1Gb Ethernet Pass-Thru Module (406740-B21) HP 10GbE Pass-Thru Module (538113-B21) QUESTION 7 When you try and boot a previously installed operating system, a BL495c G6 Server Blade freezes.
B. 4 C. 8 D. 16 Correct Answer: D Section: (none) Explanation Explanation/Reference: HP ProLiant BL685c G6 Server Blade Data sheet: Two integrated dual-port 10 Gb Ethernet server adapters with HP Virtual Connect Flex-10 technology enable up to 16 ports of Ethernet connectivity, reducing the need to add costly adapters, switches, or cables QUESTION 10 How does a c7000 enclosure retain air handling integrity when a fan is removed? A. B. C. D. The enclosure design uses blank panels to prevent air loss.
A. B. C. D. network link fault link activity at 1 Gb/s prefailure warning switch failure Correct Answer: B Section: (none) Explanation Explanation/Reference: Port 1–4 port status Green = Port is connected to the network Amber = Fault (solid) Off = Not connected Port 1–4 link/activity Green flashing = 10/100 activity Port 1–4 link/activity Amber flashing =1000 activity QUESTION 13 In a c7000 enclosure, you notice a fan LED flashes amber for about eight seconds and then returns to green.
Section: (none) Explanation Explanation/Reference: Using HP Insight Diagnostics Offline (SmartStart) Edition The Test tab provides a set of tests that allow you to test the whole server or individual components.The Insight Diagnostics Test feature lets you test the functionality of all the major hardware components in the system.
Answers: Software Support>>>>>>>>>>>>>>>>>>>>>>>>>> Not Included In An HP Warranty Flexible Support Levels>>>>>>>>>>>>>>>>>>>>>> Not Included In An HP Warranty Parts and Labor>>>>>>>>>>>>>>>>>>>>>>>>>>> Included In An HP Warranty Downtime Protection As Needed>>>>>>>>>>>>>>> Not Included In An HP Warranty Hardware Protection Against Manufacturer Defects>> Included In An HP Warranty Select and Place: Correct Answer: Section: (none) Explanation Explanation/Reference:
QUESTION 16 After replacing a defective memory module, you boot the latest version of SmartStart so you can run a custom diagnostic test to ensure that previous problems have been resolved. After loading HP Insight Diagnostics, which tab should you choose to set up a user-defined memory test? A.
B. Diagnose C. Quick Test D. Custom Test Correct Answer: D Section: (none) Explanation Explanation/Reference: Figure 3-6 Test tab – Complete Test The Status tab displays test progress. The logs, on the Log tab, display detailed test results. Running a Custom Test 1. Click Custom Test. 2. Select the test mode: • Interactive runs all tests, some of which require user input. • Unattended runs the tests that do not require user input. 3.
6. Click Begin Testing. QUESTION 17 How can a ProLiant server running Linux be rebooted from a remote location? A. B. C. D.
Access (DMA) operations, initiated by I/O devices. This feature is called double chip sparing, as 2 of 72 total DRAMs in a rank can fail without any loss of server blade performance. QUESTION 19 Which processor type is used with the HP BL460c G6 Server Blade? A. B. C. D.
Telnet (SMASH/CLP) 50023 (default) Telnet command-line interface using SMASH/CLP SSH (SMASH/CLP) 50022 (default) Secure Shell (SSH) command-line interface using SMASH/CLP Can't verify the third connectivity type QUESTION 22 What is the maximum number of SB1760c Tape Blades that can be installed in a c7000 blade enclosure? A. B. C. D.
Answer:
Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference:
The Onboard Administrator can be managed locally, remotely, and through HP SIM tools. The Onboard Administrator also provides local and remote management capability through the Insight Display and browser access. QUESTION 24 What happens when you turn the enclosure UID to "On" on the Insight Display of a c7000 enclosure? A. B. C. D. The rear enclosure UID LED illuminates and the color of the Insight Display changes to blue.
B. Power Manager C. Onboard Administrator D. Insight Display Correct Answer: C Section: (none) Explanation Explanation/Reference: BladeSystem Management and Configuration Module 7 Rev 12.31 Features of OA include: Power allocation and control for all blades and interconnects QUESTION 26 DRAG DROP Place each server blade on its recommended application type. Answer: BL870C>>>>>>Mission Critical BL460C>>>>>>Enterprise Data Center BL2x220C>>>> Scale-out HPC Web.
QUESTION 27 HOTSPOT Click on the SB600c All-in-One Storage Blade in the graphic.
Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference: SB600c QUESTION 28 Which HP blade comes with a license for Microsoft Cluster Server (MSCS)?
A. B. C. D. BL490c BL870c X3800sb xw2x220c Correct Answer: C Section: (none) Explanation Explanation/Reference: QuickSpecs HP X3800sb Network Storage Gateway Blade The X3800sb also includes a Microsoft Cluster Server (MSCS) license and Microsoft iSCSI Software Target. QUESTION 29 DRAG DROP Place the preventive measure steps in the correct order.
QUESTION 30 Which utilities can be used to scan for malware on a Windows server? (Choose two.) A. B. C. D.
QUESTION 32 HOTSPOT Click the area of the graphic where you can view real time diagnostic error information.
Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference: Integrated Management Log The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.
A. B. C. D. Test Log Error Log Integrated Management Log (IML) Sys Log Correct Answer: C Section: (none) Explanation Explanation/Reference: Integrated Management Log displays POST errors and diagnostic errors. The IML records system events, critical errors, power-on messages, memory errors, and any catastrophic hardware or software errors that typically cause a system to fail. The IML enables the manipulation of this data.
QUESTION 36 You want to connect to a ProLiant Server Blade that has the iLO port available. What must you do to connect a laptop for a direct connection to the Onboard Administrator? A. Connect a hub/switch between the laptop and the ProLiant Server Blade iLO port. B. Use a CAT 5 cross-over cable.
C. Use a standard CAT 5 cable. D. Use a CAT 5e cable. Correct Answer: C Section: (none) Explanation Explanation/Reference: Item Description 1 Onboard Administrator Ethernet connection. Use a CAT-5 patch cable to connect to the management network. This is the connector for the IP address of the Onboard Administrator and for the iLO ports on each server blade. 2 USB port for an external CD/DVD drive. 3 Used for the CLI. Connects to a laptop or computer with a null-modem serial cable (RS-232).
Section: (none) Explanation Explanation/Reference: netstat (network statistics) is a command-line tool that displays network connections (both incoming and outgoing), routing tables, and a number of network interface (network interface controller or software-defined network interface) and network protocol statistics. It is available on Unix, Unix-like, and Windows NT-based operating systems.
Answer: Green>>>>>>>Indicates System Health Is Good Blue>>>>>>>>Indicates Enclosure UID Is Active Amber>>>>>>Indicates System Health Degraded Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference: QUESTION 41 DRAG DROP Identify the correct enclosure DVD status for each enclosure.
Answer: Black — Drive is not installed in the enclosure. Light gray — Drive is present but no media is loaded. Dark green — Media is present but the drive is not connected to server bays. Light green — Drive contains media and is connected to server bays.
The Insight Display shows the DVD-ROM drive status on the Health Summary screen as a color-coded DVD icon. The color of the DVD icon varies with the status of the DVD-ROM drive: Black — Drive is not installed in the enclosure. Light gray — Drive is present but no media is loaded. Dark green — Media is present but the drive is not connected to server bays. Light green — Drive contains media and is connected to server bays.
D. Version Control Repository Manager (VCRM) Correct Answer: C Section: (none) Explanation Explanation/Reference: The VCA enables administrators and operators to perform the following tasks to maintain the software inventory of the server: View the currently installed software. Select a VCRM as a reference point for obtaining software updates . Select whether to use a Custom Software Baseline or PSP as a managed baseline.
Section: (none) Explanation Explanation/Reference: The TPM is not moved but replaced. A new TPM will be provided and there is no transferring of key. After installing the new system board and TPM module or moving encrypted disks to new server (really same effect to the data) when the user attempts to the boot the OS they will be prompted for their recovery key. Once they provide the correct key they can then rebind the OS to the new system/TPM/configuration. In the case of Microsoft's Bit Locker...
From the main menu shown in the exhibit, which menu should you select from Insight Display to check the Onboard Administrator Service IP address? A. B. C. D. Health Summary Enclosure Settings Enclosure Info Blade or Port Info Correct Answer: B Section: (none) Explanation Explanation/Reference: Enclosure Settings Menu From the Enclosure Settings Menu, you can configure the enclosure, update settings,and make changes directly from the rack.
A customer reports that Insight Display shows five NICs installed in a half-height server blade, but a connection to only two of them can be established. What could cause this to happen? A. B. C. D. The NICs and interconnect modules are running different firmware revisions. The NICs and iLO share the same interface. Some interconnect modules are powered off. The NICs are multifunction cards and also operate in iSCSI mode.
QUESTION 51 You have to update firmware of the Onboard Administrator (OA) but you have no access to the GUI.
A. B. C. D. FTP/TFTP server with OA firmware image available OA certificate applied on the machine from which the update is performed service account credentials access to the Insight Display service menu Correct Answer: A Section: (none) Explanation Explanation/Reference: Recovering from a firmware flash disaster If your Onboard Administrator encountered an error during a firmware update, you can use the following process to recover: 1.
Correct Answer: A Section: (none) Explanation Explanation/Reference: The answers for this question are all off. For HP-UX, the configuration settings are preserved in the /opt/hpsmh/conf.common/smhpd.xml file. For Windows systems The configuration settings are carried over from the \hp\hpsmh\conf\smhpd.xml file, and the wizard initiates the configuration. QUESTION 54 When connected via a remote iLO session to a new ProLiant Server Blade, how should the system BIOS settings be configured? A. B. C. D.
Note For this exercise, the configuration file is saved in the C:\Classfiles\Class setup folder (file named OAConfigScript.txt). b. URL — Enter an http:// path to the configuration file if it is located on a web server. The maximum number of characters in the file path is 256. QUESTION 56 Which server blade is based on AMD Opteron Technology? A. B. C. D.
Answer: Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference: QUESTION 58 Which services and benefits do HP CarePack Services provide? (Select three.) A. dedicated technical onsite technicians B.
C. onsite deployment of products D.
QUESTION 59 What does an HP warranty include? (Select two.) A. software support B. parts and labor C.
D.
QUESTION 60 Which information is required for a warranty check for a BL490c G6 Server? (Select three.) A. B. C. D. country/region serial number date of purchase product number Correct Answer: ABD Section: (none) Explanation Explanation/Reference: QUESTION 61 Disk drive technology used in RAID storage creates logical drives from physical units. With RAID 5, how many physical I/O requests are generated for each logical write? A. B. C. D.
Mirrored memory — Provides protection against failed Fully Buffered DIMMs; supports up to 8GB of active memory and 8GB of mirrored memory using 2GB Fully Buffered DIMMs QUESTION 63 Which capability does Intel QuickPath technology provide? A. automatically allows a processor core to run faster than the base operating frequency if it is operating below power, current, and temperature specification limits B.
You may lose data if you force eject a cartridge. The tape may also become unreadable because an EOD (End of Data) mark may not be properly written. 3. If the cartridge is still jammed, the tape drive has failed. Contact customer service at http:// www.hp.com/support. QUESTION 65 Which HP c-Class server blade series only supports non hot-plug SATA drives? A. B. C. D.
QUESTION 66 How many processor sockets does the HP BL870c c-Class Integrity Server Blade have? A. 2 B. 4 C.
D. 16 Correct Answer: B Section: (none) Explanation Explanation/Reference: For processors Up to four Intel Itanium 9100N dual-core (DC) 1.60GHz processors, with up to 24MB L3 cache (1.2MB core L2 cache) The FSB operates at 267MHz, and since data can be transferred on each clock edge, the data transfer rate is 533 MTransfers/s (million transfers per second), peak data bandwidth approximately 8.2GB/s Processor kit SUs are: 1.60GHz/24MB Dual Core, at 533MTs/267MHz FSB (DBS) 1.
Explanation Explanation/Reference: HP BLc7000 10000 Series Rack Shipping Bracket Option NOTE: The shipping bracket is required when shipping a c7000 enclosure when installed in a rack. It is not required for normal operation. PART 433718-B21 QUESTION 68 When a customer is using a StorageWorks 3Gb SAS BL Switch in the c7000 enclosure, what can be connected? A. B. C. D.
C. from top to bottom, then left to right D.
QUESTION 71 If time is critical and all memory tests in the HP Insight Diagnostics Offline Edition cannot be run, which memory tests should be run? (Select two.) A. B. C. D. address random address read noise Correct Answer: BD Section: (none) Explanation Explanation/Reference: To test memory thoroughly, run as many loops as possible in the time allowed. If time is critical, and all memory tests cannot be run, then HP recommends running the Random Address test and the Noise test.
Explanation Explanation/Reference: Press F9 to access RBSU QUESTION 73 A BL490c G6 processor has been replaced. The customer wants the new processor to be tested for several hours before placing the server blade back in service. In order to accomplish this, what should you do after loading HP Insight Diagnostics Offline Edition? A. B. C. D. Choose an unattended quick test with a time limit. Choose a complete test with a time limit. Run an unattended quick test with a time limit.
Explanation Explanation/Reference: Configuration guidelines for online spare memory Online spare memory must be configured using the ROM-Based Setup Utility. To configure memory for Online Spare mode on a server that supports it, the following configuration requirements must be met: Memory banks must be designated, for example A through D. Memory must be populated sequentially, starting with bank A. DIMMs within a bank must be identical (same capacity and number of ranks).
A. B. C. D. QLogic or Emulex HBA mezzanine card InfiniBand mezzanine card P700 Smart Array mezzanine card PCI Express Mezzanine Pass-Thru Correct Answer: Section: (none) Explanation Explanation/Reference: Q2. When do I need this expansion card? A2. The PCIe Mezzanine pass-thru card is for connecting a full height c-Class BladeSystem server to the SB40c storage blade. QUESTION 79 What should be done after a repair has been validated? A. B. C. D. The IML log entry should be marked as repaired.
Correct Answer: C Section: (none) Explanation Explanation/Reference: How to collect crash dump files on Windows 2008 and Windows 2008 R2 Solution Overview: What happened to Dr. Watson in Windows 2008? Dr. Watson was replaced with Problem Reports and Solutions. Troubleshooting: During the course of NetBackup troubleshooting, it might be necessary to analyze why a NetBackup process has performed an Application Fault.
A. B. C. D. when the RAID set is rebuilt when the server is not busy when the server is powered off when the drive fails completely Correct Answer: A Section: (none) Explanation Explanation/Reference: HP says to replace a drive in predictive failure as soon as possible but since its not an option I guess the next best thing to do is wait for the raid to finish rebuilding.
QUESTION 87 Which serial communication parameters must be set on the terminal emulator to connect the Onboard Administrator? A. B. C. D. 9600 E, 8, 1 19200 E, 7, 1 19200 N, 7, 1 9600 N, 8, 1 Correct Answer: D Section: (none) Explanation Explanation/Reference: If you have two Onboard Administrator modules in the enclosure and you want to Flash Recover theActive OA: a. With a null-modem cable (9600 N, 8, 1, VT100),locally connect to the Onboard Administrator. b.
5. To boot the system into Lost Password modem Press L. The password appears as the system reboots. QUESTION 89 Which action prevents changing settings in the c7000 Insight Display? A. B. C. D.
Correct Answer: D Section: (none) Explanation Explanation/Reference: QUESTION 92 Which command can be used to display the currently installed EFi on a BL870c Server Blade? A. B. C. D.
Explanation/Reference: HP Integrity BL870c Server Blade User Service Guide: EFI Commands: infoDisplays most server information.
Select and Place: Correct Answer: Section: (none) Explanation Explanation/Reference: QUESTION 94 Which feature of the Ultrium 448 Tape Blade allows quick recovery of the operating system? A. B. C. D.
What should you do to determine the list of hotfixes installed on a Windows server? A. B. C. D. Run regedit and look under HLM\Software\Microsoft\Windows\CurrentVersion\HotFix. Open the Windows Update applet in the control panel. Use the systeminfo command. Right-click on My Computer and select the Advanced tab. Correct Answer: C Section: (none) Explanation Explanation/Reference: From a dos prompt, run systeminfo. This will generate the info that you can then copy and paste into a text file.
If only one hard drive is used, install it in the bay with the lowest drive number. Drives must be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array. QUESTION 98 Which firmware can be upgraded using HP SUM running on a Windows-based ProLiant? A. B. C. D.
QUESTION 100 Which HP solution can be used to integrate a "phone-home" solution for an HP BladeSystem customer? A. HP Warranty and Service Advisor B.
HP Warranty and Service Automation C. HP Insight Remote Support Standard D. HP Insight Control for BladeSystems Correct Answer: D Section: (none) Explanation Explanation/Reference: HP Insight Control is essential server management that unleashes the management capabilities built into every HP ProLiant server. The result is superior management of physical and virtual servers, from any location.
D. Select the Synchronize Firmware button in either OA. Correct Answer: D Section: (none) Explanation Explanation/Reference: The current firmware version installed on the Onboard Administrator, Active and Standby if there is more than one, appears on theFirmware Update screen. The current Onboard Administrator hardware version also appears on this screen. To update the Onboard Administrator to the same version of firmware, click Synchronize Firmware.
B. The hard drives failed. C. There is no hard drive activity. D. The hard drives are not configured by a RAID controller. Correct Answer: C Section: (none) Explanation Explanation/Reference: QUESTION 106 After a BL460c G7 system board replacement due to a mismatched processor support error, the engineer performs a firmware verification and update process. As a preventive measure, which firmware must be checked and updated, if required? A. the primary firmware on the system board B.
Answer: Point and Shoot: Correct Answer:
Section: (none) Explanation Explanation/Reference: QUESTION 108 When connected to the c7000 or c3000 enclosure service port how does a Windows-based laptop configured for DHCP acquire its IP address? A. The laptop will receive an address in the 192.168.x.x address range from the DHCP server within the enclosure B. The laptop will receive an address in the 169.254.x.x address range from the DHCP server within the enclosure C.
• Up to two HP hot-plug internal disk drives and the HP Smart Array P410i controller with 1 GB flash-backed write cache (FBWC) • HP advanced power monitoring and management QUESTION 110 How often does the Hardware Status Polling task within HP SIM check communications status with all discovered devices? A. B. C. D.
The HP BladeSystem c7000 rack enclosure is 10U high and holds up to 16 ProLiant BL2x220c Blades (32 server nodes) plugged vertically. NOTE: Ten (10) fans are required in the c7000 enclosure. NOTE: N + N power supply redundancy is not supported. N + 1 power supply redundancy is supported. NOTE: The BL2x220c G6 is not supported in the c3000 enclosure. QUESTION 113 Which utility should you use to gather detailed information about SNMP traffic on a Windows server? A. Microsoft Performance Monitor B.
Explanation Explanation/Reference: Observe the booting process and wait for the F9 prompt. QUESTION 116 Click the area of the graphic where you view diagnostic test error information.
Answer: Point and Shoot: Correct Answer:
Section: (none) Explanation Explanation/Reference: To view all test failure information, view the Error Log on the Log tab.
QUESTION 119 What is available as part of Advanced Infrastructure management on HP BladeSystems? A. B. C. D. automatic installation of HP System Management Homepage dynamic balancing of physical and logical resources HP's improved secure SNMP single console to display information about multiple devices Correct Answer: B Section: (none) Explanation Explanation/Reference: QUESTION 120 Click on an Onboard Administrator module in the graphic.
Point and Shoot: Correct Answer: Section: (none) Explanation Explanation/Reference:
QUESTION 121 Click on the Ethernet pass-thru module in the graphic.
Correct Answer: Section: (none) Explanation Explanation/Reference: QUESTION 122 \Which HP mezzanine option supports hardware RAID for Solid State Drives (SSDs)? A. HP PCI Express Mezzanine Pass-Thru card B. HP StorageWorks IO Accelerator C. HP Smart Array P712m Controller D.
Explanation Explanation/Reference: The HP PCI Expansion Blade provides PCI card expansion slots to an adjacent cClass server blade. It allows customers to add off-the-shelf PCI-X or PCI-e cards to these server blades – up to two PCI-X or up to two PCI-e cards (these cannot be mixed). QUESTION 125 What can be used to prevent the mixing of hot and cold air to improve the cooling efficiency of c-Class enclosures installed in the 10000 Series cabinet? (Select two.) A. B. C. D.
Section: (none) Explanation Explanation/Reference: QUESTION 127 What should a system engineer use to back up the configuration for a BladeSystem enclosure? (Select two.) A. Onboard Administrator GUI - Configuration Scripts option B. Onboard Administrator GUI - Rack Overview option C. Insight Display - Enclosure Settings D.
256MB ECC protected cache. An application runs slowly whenever there are large bursts of disk writes. How can this be prevented? A. by adding more internal disks to distribute the load B. by creating a larger swap file to handle the extra load C. by changing the internal disks from RAID 1 to RAID 5 D.
Correct Answer: D Section: (none) Explanation Explanation/Reference: QUESTION 131 The customer has a single Onboard Administrator (OA), which needs to be replaced. What should you do before you replace the OA? A. Access the OA GUI or CLI and capture a system log. B. Telnet or SSH to the OA and collect a showall.txt. C. Browse to the OA and collect a script containing a list of the enclosure's current inventory. D. Use a USB key and the Insight Display to save the configuration.
QUESTION 133 What is used to automatically download software updates from HP? A. HP Subscribers Choice B. Version Control Agent (VCA) C. HP Systems Insight Manager (HP SIM) D.
Version Control Repository Manager (VCRM) Correct Answer: D Section: (none) Explanation Explanation/Reference: The software and firmware can be manually downloaded from http://www.hp.com directly to this directory, or you can use the capabilities of the Version Control Repository Manager to automatically download software or manually upload software from any Web client. QUESTION 134 Your customer uses a c3000 enclosure with only one Virtual Connect Flex 10 module in bay 1.
The customer replaced a server blade that had been backed up to an Ultrium 448 Tape Drive. How should you restore the server blade and have it fully functional? A. During POST, you select F9 to restore from tape. B. You power up the server blade and hold down the One-Button Disaster Recovery (OBDR) button. C. You insert the tape that has the backup of the server, then power up the blade. D. You power up the blade and select F9 during POST to enter into the RBSU.
Explanation/Reference: Through BIOS Serial Console and EMS console redirection, you can view POST error messages and run RBSU remotely through a serial connection to the server COM port or iLO Virtual Serial port. The remote server does not require a keyboard or mouse. QUESTION 138 Which statement is true about creating a repository for implementing Version Control Repository Manager (VCRM)? A. There can be only one repository in the customer's environment. B.
QUESTION 140 Which statement is true about the background color of the Insight Display? A. If there is an error detected in the Insight Display, the background color will be amber regardless of the status of the enclosure UID indication B. If the enclosure UID is active, the Insight Display background color will be blue C. An Insight Display background color of green will override a red error indication D.
B. OA Management Homepage C. Onboard Administrator CLI D. Insight Display Correct Answer: B Section: (none) Explanation Explanation/Reference: QUESTION 143 What is required to recover from a failed Onboard Administrator (OA) firmware upgrade? (Select three.) A. local access to the enclosure B. a DHCP and FTP server accessible by OA C. OA firmware in a .bin file D.
A. ASR implemented on the OA level B. enclosure link-down port C. enclosure Reset button at the rear of the enclosure D. Insight Display Correct Answer: D Section: (none) Explanation Explanation/Reference: QUESTION 145 Which port must be used to connect to the Onboard Administrator (OA) using Service IP? A. any port of the interconnect in bay 1 B. USB port on active OA C. standby OA network port D.
A customer installed sixteen server blades and two GbE2c switches in a c7000 enclosure. The customer reports that none of the servers have a LAN connection. How you can solve this problem? A. Enable iSCSI and RDMA options for embedded multifunction NIC cards. B. Verify GbE2c switches are installed into bays 1 and 2. C. Replace GbE2c switches with the Flex-10 10 Gb Ethernet module to manage all LAN interfaces. D. Install two additional LAN GbE2c switches into bays 5 and 6 to cover all LAN interfaces.
Section: (none) Explanation Explanation/Reference: Integrated Lights-Out Advanced Pack provides HP customers with an easy upgrade to full Lights-Out functionality on their Integrated Lights-Out Standard enabled ProLiant servers.
QUESTION 150 Which resource can be used to identify the warranty status of an HP BL460c G6 Server Blade? A.
B. HP Service Advisory C. HP Onboard Administrator D. HP Service Dashboard Correct Answer: A Section: (none) Explanation Explanation/Reference: IT Resource Center The ITRC can provide you with instant information regarding the warranty status for any of your HP Enterprise products. A warranty check tool displays the details of product warranties for specific serial numbers. Click warranty check on this web page: http://www2.itrc.hp.
D.
QUESTION 1 If you install two Onboard Administrator modules in a c7000 enclosure with different firmware revisions, which module will be active by default ? A. B. C. D.
A. B. C. D. 2 4 6 8 Correct Answer: A Section: (none) Explanation Explanation/Reference: Fan location rules The c7000 enclosure ships with four Active Cool 200 Fans and supports up to 10 fans. Install fans in even-numbered groups, based on the total number of server blades installed in the enclosure: Four server blades — Install fans in bays 4, 5, 9, and 10. Six server blades — Install fans in bays 3, 4, 5, 8, 9, and 10. Eight server blades — Install fans in bays 1, 2, 4, 5, 6, 7, 9, and 10.
! Important If the fans are not in these exact locations, the thermal subsystem will be degraded and no newly inserted server will be allowed to power up. QUESTION 3 An engineer is trying to insert an I/O Accelerator card into a blade server. Which mezzanine slot is appropriate? A. B. C. D.
Correct Answer: A Section: (none) Explanation Explanation/Reference: HP Virtual SAS Manager HP Virtual SAS Manager (VSM) is embedded in the 3Gb SAS BL Switch firmware and is the software application used to create hardware-based zone groups to control access to external SAS storage enclosures and tape devices.
B. CSR Advance Unit Replacement C. CSR express D. CSR mandatory Correct Answer: D Section: (none) Explanation Explanation/Reference: Currently, HP identifies two types of Customer Self Repair parts - 'Mandatory' and 'Optional'. 'Mandatory' requires standard warranty customers to perform part replacement or pay for HP service. Self repair is optional for customers with an HP Care Pack or support agreement.
QUESTION 8 How many power supplies are needed for an (N+N) configuration in a c7000 enclosure? A. B. C. D. 3 4 5 7 Correct Answer: B Section: (none) Explanation Explanation/Reference: AC Redundant In the N+N AC Redundant power mode, a minimum of two power supplies is required. N power supplies provide power and N provides redundancy, where N can equal 1, 2, or 3. QUESTION 9 Which memory configuration types are supported in the Gen8 ProLiant Blade servers? (Select two.) A. B. C. D. E.
A. B. C. D. E. Syslog log System Event log Forward Progress log Machine Check log Resource Monitor log Correct Answer: BC Section: (none) Explanation Explanation/Reference: Explanation: RRL: Manual HP Integrity iLO 3 Operations Guide, Seite 35 QUESTION 11 Which feature should you enable in RBSU in a G7 server to reduce processor power usage and improve overall performance in some applications? A. B. C. D. E.
Section: (none) Explanation Explanation/Reference: Reference:http://www.scribd.com/doc/46311510/10/Processor-Options-G7-servers(p.
Explanation/Reference: Power Supply Redundant The graphic shows two circuits (circuit A and B) being used. This is possible but not necessary for the power supply redundant mode. Total power for the c7000 enclosure is total power available, less one power supply. A 5+1 configuration = 12000W. The c3000 enclosures can provide up to 6000W in a 5+1 configuration.
QUESTION 14 You installed an FC HBA in mezzanine slot 2 of a BL460c G6 in a c7000 enclosure. In which interconnect bays should the FC interconnect be installed? A. B. C. D.
Section: (none) Explanation Explanation/Reference: Interconnect bay numbering and device mapping To support network connections for specific signals, install an interconnect module in the bay corresponding to the embedded NIC or mezzanine signals.
A. B. C. D.
QUESTION 16 Which HP Gen8 Blade Server function constantly records configuration, performance, and optional data? A. B. C. D. Active Health Integrated Management Log Health Agent Event Log Correct Answer: A Section: (none) Explanation Explanation/Reference: The Gen8 Active Health System provides a log of historical information including the most recent states and events for Gen8 servers. This log is obtained from Gen8 Server Blades via iLO4.
In which direction does the air flow through a c7000 enclosure? A. B. C. D. E. bottom to top front to back top to bottom back to front back to front Correct Answer: B Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 19 Where does Active Health collect the data from? A. B. C. D. Event Log SMH IML iLO Correct Answer: D Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03207602/c03207602.
Current Version New Version BladeSystem c7000 Onboard Administrator Tray 1.2 1.2 BladeSystem c7000 Insight Display 2.2.2 2.2.2 BL c-Class PCI Expansion Blade 15 1.20 2.26 HP 4Gb Fibre Channel Pass-thru Module for c-Class 3A 2.4.3 2.10.3 From the above example, PCI Expansion Blade current firmware is 1.20 and available version is 2.00 To update the firmware on PCI Expansion Blade, run the command >UPDATE DEVICE XX Where XX stands for location.
In the exhibit shown, what does the LED illuminated circle within the red square on the disk drive handle carrier for a Gen8 server indicate? A. B. C. D. There is drive activity. It is safe to unplug the drive. The drive is not part of an array. Do NOT unplug drive. Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 24 What are some general requirements that must be met to update Virtual Connect firmware? (Select three.) A.
Explanation Explanation/Reference: Reference:http://h18004.www1.hp.com/products/quickspecs/13652_div/13652_div.PDF(page 3, overview, second bulleted point) QUESTION 26 What must be used to update Virtual Connect firmware above version 3.0x when VCEM is used and managing other domains? A. B. C. D.
QUESTION 29 What must be verified when replacing the Virtual Connect FlexFabric modules in a c7000 enclosure? A. B. C. D.
D. Data loss may occur. Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: Product Bulletin, definitiv D! QUESTION 33 What should you use to check the overall health status of all the BL460c Gen8 servers you recently installed in a c7000 enclosure? A. B. C. D.
Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 36 In RBSU, which profile setting takes precedence over the NIC Personality option in a G7 server? A. B. C. D. E. ICSI network server mode virtual connect embedded NIC FCoE Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 37 Which OA GUI virtual power button command powers the server on or off gracefully? A. B. C. D. E.
Correct Answer: A Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02885443/c02885443.pd f(page 5, see the bulleted points for the deployments where the operating system has been installed on the servers) QUESTION 39 You want to add memory to an existing BL890c i2 server. The new DIMMs have a different size than the installed ones. Which memory upgrades guideline is correct? A.
A. B. C. D. E. F. G. Correct Answer: F Section: (none) Explanation Explanation/Reference: Explanation: Bay F !!! QUESTION 41 Which technologies are supported on a G7 or Gen8 server blade when the appropriate mezzanine card is installed in a server along with the FlexFabric interconnects? (Select two.
A. B. C. D. E. iSCSI Infiniband Accelerated Ethernet Adaptive FC FCoE Correct Answer: AE Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 42 Which HP ProLiant software tool should you use to deploy an OS to a BL460c Gen8 server? A. B. C. D.
Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 45 The BL460c G6 can access the adjacent processor's memory using which bus? A. B. C. D. Fast Memory Channel HyperTransport bus NUMA-b Quick Path interconnect Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 46 Which benefit is provided by having identical Interconnect modules in adjacent bays of the c7000 enclosure? A. B. C. D.
QUESTION 48 A customer has a BL460c Gen8 server. What are the recommended DDR3 memory installation guidelines? (Selcet three.) A. B. C. D. E. DIMMS of different voltages may not be mixed. To maximize performance, balance the total memory capacity between all installed processors. The memory channels must be loaded with the same size memory DIMM. White DIMM slots should be populated first. If only one processor is installed, only half the DIMM slots are available.
A customer replaced the memory DIMM several times in the same slot on a BL460c G7 Server. What are the next troubleshooting steps? (Select two.) A. B. C. D. E. Run the Insight Diagnostics Online Edition. Swap the DIMM with a known good DIMM from a different slot. Swap the first and second processor, if available. Run the Insight Diagnostic survey to verify hardware changes. Run the Insight Diagnostics Offline Edition.
How should you do this ? A. Conect to the serial port of the Onboard Administrator and press the reset button to restore the default password. B. Rund Remote Insight Board Command Language (RIBCL) from the Insight Display. C. USE HP SUM in recovery mode. D. Use on of the blades and run the Onboard Administrator recover option. Correct Answer: A Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 55 An engineer needs to install a UPS R8000/3 in an HP 10636 G2 rack.
C. The hard drives failed. D. Smart Array Advanced Pack (SAAP) single server license was not installed. Correct Answer: A Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 58 An administrator is struggling with the configuration of a c7000 enclosure and calls HP support for assistance. What is the best way to forward the inventory and event logs to HP support. A. B. C. D. Capture the screen shots of the c7000 enclosure settings through OA.
Explanation Explanation/Reference: Explanation: QUESTION 61 Which HP tool is used to configure NIC teaming on a Windows server? A. B. C. D. ORCA PCM+ RBSU NCU Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 62 A customer wants a basic power configuration for a c7000 enclosure using only single-phase power. Which power supply slots in the enclosure must be populated to meet the requirement for N+1 redundancy? A. B. C. D.
A customer has a c7000 enclosure that is fully populated with BL680c blades. Two months after the initial installation, the rack initiates a thermal shutdown. When diagnosing the problem, you find there is not enough space to get behind the unit. You pull all the units out but find no problems with the chassis, blades, or their cooling systems. What is a potential cause for the thermal shutdown? A. The rack is too close to the cold air outlet.
Explanation/Reference: Explanation: QUESTION 67 When using the HP Online Diagnostics Utility on a BL460c server, which component information cannot be tested using the online tool? A. B. C. D. total memory video controllers network cards array controllers Correct Answer: A Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 68 Which HP tools should be used to determine that an SSD drive has degraded due to a high number of write operations? (Select three.) A. B. C. D. E.
Which HP utility will patch a ProLiant with a release set made up of drivers, firmware and software that have been tested together? A. B. C. D. HP Smart Update Firmware DVD Service Pack for ProLiant (SPP) Integrated Lights Out (ILO) HP Version Control Update (VCU) Correct Answer: B Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 71 An HP VC Flex-10 module must be replaced in a c3000 BladeSystem enclosure because one uplink port is defective.
A. B. C. D. Connect an SUV to the VM module. Enable the iLO Advanced license in RBSU. Enable graphics mezzanine support. Connect an SUV cable to the blade. Correct Answer: D Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 74 You installed two hard drives in a BL460c Gen8 server. Both the hard drive status LEDs are off. What is a possible cause? A. B. C. D. Smart Array Advanced Pack (SAAP) single server license was not installed. The hard drives failed.
D. SPP is the replacement for the Service and Diagnostics tools. Correct Answer: A Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 77 After replacing a system board on a ProLiant BL460c G7, which steps are required to ensure that the license status remains intact in an HP Matrix Operating Environment? (Select two.) A. B. C. D. E. F. Use HP Systems Insight Manager License Manager to re-apply the license. Set the Unique Unit Identifier in the system ROM.
Section: (none) Explanation Explanation/Reference: Reference:http://webcache.googleusercontent.com/search?q=cache:R4XUUoht8rwJ:bizsupport1. austin.hp.com/bizsupport/TechSupport/Document.jsp%3FobjectID%3Dc01209399%26lang%3Den %26cc% 3Dus%26taskId%3D101%26prodSeriesId%3D3884098%26printver%3Dtrue+&cd=4&hl= en&ct=clnk(see bulleted point 10) QUESTION 80 Which processor type is used with the HP BL460c G6 Server Blade? A. B. C. D.
Explanation/Reference: Reference:http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c01327127/c01327127 .pdf(page 145) dmpstore = Display EFI variables bcfg = Display and modify the Driver and boot config nvrambkp = correct ! nvramsave = ??? QUESTION 83 Which command allows you to break out to a Linux console session while booted to the HP Smart Update Firmware DVD to access debug trace logs to diagnose an update failure? A. B. C. D.
Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03306157/c03306157.pd f(page 2, overview of HP agentless management, firsts paragraph) QUESTION 86 Where can you verify the status of an external DVD-ROM drive in a c7000 enclosure? A. B. C. D.
Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c03293145/c03293145.pd f(page 11 and 12) QUESTION 88 Which mezzanine card allows Fibre Channel and Ethernet connectivity through the same interconnect module? A. B. C. D.
QUESTION 91 Which external storage type allows a customer to share common LUNs between servers and booting operating systems? A. B. C. D. NAS SAN MDS DAS Correct Answer: B Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 92 A customer is experiencing a pre-failure alarm of the UPS Battery on a UPS that is almost one year old. Which statement is correct? A. B. C. D. The battery replacement is included in the warranty.
B. Intelligent Provisioning C. Systems Management Homepage D. SmartStart Correct Answer: B Section: (none) Explanation Explanation/Reference: Reference:http://hpproliant.blogspot.com/2012/06/install-windows-sbs-2011-in-hp-gen8.html QUESTION 95 Which tool can be used to deploy firmware and software updates to a ProLiant blade? A. B. C. D.
Explanation Explanation/Reference: Reference:http://www.netsquirrel.com/msconfig/index.html QUESTION 98 How should you save a Virtual Connect configuration? A. B. C. D. from CLI: show all > cfg.
Which tool can be used to upgrade the firmware of Virtual Connect Ethernet module? (Select two.) A. B. C. D. E. HP SUM OA VCSU VCEM HP SIM Correct Answer: AC Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bizsupport/TechSupport/Document.
A. B. C. D. advanced diagnostics for fault isolation PXE boot device selection shortcut keys under OS control function key selection during startup Correct Answer: B Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 105 HOTSPOT Match the appropriate HP best practices rack location with each listed component to configure the rack shown.
A. Answer: Location 1 - network switch Location 2 - c7000 enclosure Location 3 - UPS 8000 /3 Location 4 - rack stabilization kit Correct Answer: A Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 106 You have a c7000 enclosure with 1 GB Pass-Thru modules. You cannot get to the network from any of the blades. What should you verify first for proper connectivity to the network? A. B. C. D.
QUESTION 107 You are installing a new HP BladeSystem c7000 enclosure. The customer wants to configure the iLO and interconnect IPs so that they are automatically maintained during a hardware swap. How should you configure the enclosure? A. B. C. D. Use the Insight Display fixed IP feature. Use Enclosure-Based IP Addressing. Use Insight Control Server Deployment to configure the enclosure. Configure the IP on each device and enable enclosure IP mode.
QUESTION 110 A server has been shutting down sporadically for the past two months. VCRM is not installed and configured. Where can you locate the latest versions of firmware that are available for this server? A. B. C. D.
A. B. C. D. E. F. The potential for condensation increases when humidity increases. When humidity decreases within the data center, flexible joints become fragile. When humidity increases, the potential for ESD increases. The potential for condensation decreases when humidity decreases. When humidity increases within the data center, flexible joints become fragile. When humidity decreases, the potential for ESD increases.
A. B. C. D. OA, server blades (online/offline), then VC server blades (online/offline). VC then OA VC, OA, then server blades (online/offline) You cannot do this; the VC firmware needs to be installed first. Correct Answer: A Section: (none) Explanation Explanation/Reference: Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01857420/c01857420.pd f(page 21, If an operating system has already been installed) QUESTION 117 Match the backup strategies with their definitions. A.
A. B. C. D. E. F. winver msconfig patch msinfo32 swlist uname Correct Answer: BD Section: (none) Explanation Explanation/Reference: Explanation: QUESTION 119 A customer purchased a c7000 blade enclosure, fully populated with blade Gen8 servers and Care Pack services. Several days later, the customer purchased an HPZR30W, an HP UPS R8000/3, and two iPDUs. Which new items will be covered in the Care Pack services? (Select two.) A. B. C. D. E.
Which feature is supported by the zx2 chipset in the Integrity BL860c? A. B. C. D. hot spare and hot-plug of memory DIMMs up to 512GB of memory (not fully buffered DIMMs) memory DIMM error correction (chip sparing) 512-bit, 800MHz (800 MT/s, 1600MHz data rate) memory bus Correct Answer: C Section: (none) Explanation Explanation/Reference: Explanation: Integrity i2 server blade portfolio The Integrity BL860c i2 supports up to 384 GB of memory using 24 PC3-10600 Registered CAS9 memory modules.
QUESTION 122 Which feature of the BL465c G7 allows the server to accommodate 16 DIMM slots and retain the half-height form factor? A. B. C. D. PCIe Gen 2 x8 mezzanine expansion slots AMD SR5690/SP5100 chipset Hot Plug Drive Drawer Smart Array P410i Controller with 1GB FBWC Correct Answer: B Section: (none) Explanation Explanation/Reference: Explanation: Processor: Up to two (2) Multi-Core AMD Opteron™ 6200 or 6100 Series processors Sixteen-Core supports up to 2.
Turn Enclosure UID on — Enables enclosure identification LED. When selected, the display will change background color to blue, and blue LED will be visible at the rear of the enclosure. QUESTION 124 What is the maximum number of c3000 enclosures that can be installed in a 42U rack? A. B. C. D.
Server (MSCS) license.