Technical data

The following section describes how to prepare the DS-DWZZH-05 UltraSCSI
hub for use on a shared SCSI bus in more detail.
3.6.1.2.1 DS-DWZZH-05 Configuration Guidelines
The DS-DWZZH-05 UltraSCSI hub can be installed in:
A StorageWorks UltraSCSI BA356 shelf (which has the required
180-watt power supply).
A non-UltraSCSI BA356 that has been upgraded to the 180-watt power
supply with the DS-BA35X-HH option.
_____________________ Note _____________________
Dual power supplies are recommended for any BA356 shelf
containing a DS-DWZZH-05 UltraSCSI hub in order to
provide a higher level of availability between cluster member
systems and storage.
The lower righthand device slot of the BA370 shelf within the RA7000
or ESA 10000 RAID array subsystems. This position minimizes cable
lengths and interference with disks.
A DS-DWZZH-05 UltraSCSI hub uses the storage shelf only to provide its
power and mechanical support (it is not connected to the shelf internal SCSI
bus).
______________________ Note _______________________
When the DS-DWZZH-05 is installed, its orientation is rotated
90 degrees counterclockwise from what is shown in Figure 3–3
and Figure 3–4.
The maximum configurations with combinations of DS-DWZZH-03 and
DS-DWZZH-05 UltraSCSI hubs, and disks in the same storage shelf
containing dual 180-watt power supplies, are listed in Table 3–3.
______________________ Note _______________________
With dual 180-watt power supplies installed, there are
slots available for six 8.9-centimeter (3.5-inch) SBBs or two
13.33-centimeter (5.25-inch) SBBs.
Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 3–11