Technical data

of the bus segment. Termination for the other end of the bus segment is
provided by the folowing components:
Installed KZPBA-CB (or KZPSA-BB) termination resistor SIPs
External termination on a trilink connector that is attached to an HSZ40,
HSZ50, HSZ70, or HSZ80
______________________ Note _______________________
The DS-DWZZH-03/05 UltraSCSI hubs cannot be connected to a
StorageWorks BA35X storage shelf because the storage shelf does
not provide termination power to the hub.
3.6.1 Using a DWZZH UltraSCSI Hub in a Cluster Configuration
The DS-DWZZH-03 and DS-DWZZH-05 UltraSCSI hubs are supported in a
TruCluster Server cluster. They both provide radial connection of cluster
member systems and storage, and are similar in the following ways:
Contain internal termination for each port; therefore, the hub end of
each SCSI bus segment is terminated.
_____________________ Note _____________________
Do not put trilinks on a DWZZH UltraSCSI hub because it is
not possible to remove the DWZZH internal termination.
Require that termination power (termpwr) be provided by the SCSI bus
host adapters on each SCSI bus segment.
_____________________ Note _____________________
The UltraSCSI hubs are designed to sense loss of termination
power (such as a cable pull or termpwr not enabled on the
host adapter) and shut down the applicable port to prevent
corrupted signals on the remaining SCSI bus segments.
3.6.1.1 DS-DWZZH-03 Description
The DS-DWZZH-03:
Is an 8.9-centimeter (3.5-inch) StorageWorks building block (SBB).
Can be installed in:
Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware 3–9