Technical data
Figure 1–8: NSPOF Fibre Channel Cluster Using HSG80s in Multiple-Bus
Failover Mode
KGPSA
Member
System
2
KGPSA
KGPSA
Member
System
1
KGPSA
Memory
Channel
Memory
Channel
Memory
Channel
Memory
Channel
Memory Channel
Interface
Memory Channel
Interface
ZK-1765U-AI
Fibre Channel SwitchFibre Channel Switch
HSG 80
Controller A
HSG 80
Controller B
RA8000/ESA12000
Port 1
Port 2
Port 1
Port 2
If you are using LSM and multiple shared SCSI buses with storage shelves,
you need to:
• Mirror the clusterwide root (/), /usr, and /var file systems across two
shared SCSI buses.
• Place the boot disk for each member system on a separate shared SCSI
bus.
• Provide another shared SCSI bus for the quorum disk.
Introduction 1–17