Technical data
______________________ Note _______________________
It is assumed that the library robotics controller is on the same
SCSI bus as tape drive 1.
To connect the library robotics and one drive to a single shared SCSI bus,
follow these steps:
1. Connect a 328215-00X, BN21K, or BN21L between the last Y cable or
trilink connector on the bus to the leftmost connector (as viewed from the
rear) of the MiniLibrary. The 328215-004 is a 20-meter (65.6-foot) cable.
2. Install a 30-centimeter (11.8-inch) SCSI bus jumper between the
rightmost robotics connector (second connector from the left) and the
left DLT1 connector (the third connector from the left).
3. Install an HD68 differential terminator (such as an H879-AA) on the
right DLT1 connector (the fourth connector from the left).
To connect the drive robotics and two drives to a single shared SCSI bus,
follow these steps:
1. Connect a 328215-00X, BN21K, or BN21L between the last trilink
connector on the bus to the leftmost connector (as viewed from the rear)
of the MiniLibrary.
2. Install a 30-centimeter (11.8-inch) SCSI bus jumper between the
rightmost robotics connector (the second connector from the left) and
the left DLT1 connector (the third connector from the left).
3. Install a 30-centimeter (11.8-inch) SCSI bus jumper between the
rightmost DLT1 connector (the fourth connector from the left) and the
left DLT2 connector (the fifth connector from the left).
4. Install an HD68 differential (H879-AA) terminator on the right DLT2
connector (the rightmost connector).
To connect the drive robotics and one drive to one shared SCSI bus and the
second drive to a second shared SCSI bus, follow these steps:
1. Connect a 328215-00X, BN21K, or BN21L between the last trilink
connector on one shared SCSI bus to the leftmost connector (as viewed
from the rear) of the MiniLibrary.
2. Connect a 328215-00X, BN21K, or BN21L between the last trilink
connector on the second shared SCSI bus to the left DLT2 connector
(the fifth connector from the left).
3. Install a 30-centimeter (11.8-inch) SCSI bus jumper between the
rightmost robotics connector (the second connector from the left) and
the left DLT1 connector (the third connector from the left).
Configuring a Shared SCSI Bus for Tape Drive Use 8–65