Example 6–5 shows:
• The use of the wwidmgr -quickset command to set the device unit
number for the Tru64 UNIX Version 5.1A installation disk to 133,
and the first cluster member system boot disk to 131.
• The wwidmgr -quickset command provides a reachability display
equivalent to execution of the wwidmgr reachability command.
The reachability part of the display provides the following:
– The worldwide name for the storage unit that is to be accessed.
– The new device name for the storage unit.
– The KGPSA adapters through which a connection to the storage
unit is potentially available.
– The WWID of the HSG80 port(s) (N_Ports) that will be used to
access the storage unit.
– The connected column indicates whether the storage unit is
current available through the KGPSA to HSG80 controller port
connection. The HSG80 controllers are in multiple-bus failover
so each storage unit is presented by only one controller at a time.
Example 6–5: Setting the Device Unit Number with the wwidmgr quickset
Command
P00>>> wwidmgr -quickset -udid 133
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter: via fc nport: connected:
dga133.1001.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d64 No
dga133.1002.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d62 Yes
dga133.1003.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d63 No
dga133.1004.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d61 Yes
dgb133.1001.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d64 No
dgb133.1002.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d62 Yes
dgb133.1003.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d63 No
dgb133.1004.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d61 Yes
P00>>> wwidmgr -quickset -udid 131
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter: via fc nport: connected:
dga133.1001.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d64 No
dga133.1002.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d62 Yes
dga133.1003.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d63 No
dga133.1004.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d61 Yes
dgb133.1001.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d64 No
dgb133.1002.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d62 Yes
dgb133.1003.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d63 No
dgb133.1004.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d61 Yes
6000-1fe1-0000-0d60-0009-8080-0434-002f
6–64 Using Fibre Channel Storage