Technical data

Example 6–5 shows:
The use of the wwidmgr -quickset command to set the device unit
number for the Tru64 UNIX Version 5.1A installation disk to 133,
and the first cluster member system boot disk to 131.
The wwidmgr -quickset command provides a reachability display
equivalent to execution of the wwidmgr reachability command.
The reachability part of the display provides the following:
The worldwide name for the storage unit that is to be accessed.
The new device name for the storage unit.
The KGPSA adapters through which a connection to the storage
unit is potentially available.
The WWID of the HSG80 port(s) (N_Ports) that will be used to
access the storage unit.
The connected column indicates whether the storage unit is
current available through the KGPSA to HSG80 controller port
connection. The HSG80 controllers are in multiple-bus failover
so each storage unit is presented by only one controller at a time.
Example 6–5: Setting the Device Unit Number with the wwidmgr quickset
Command
P00>>> wwidmgr -quickset -udid 133
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter: via fc nport: connected:
dga133.1001.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d64 No
dga133.1002.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d62 Yes
dga133.1003.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d63 No
dga133.1004.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d61 Yes
dgb133.1001.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d64 No
dgb133.1002.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d62 Yes
dgb133.1003.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d63 No
dgb133.1004.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d61 Yes
P00>>> wwidmgr -quickset -udid 131
Disk assignment and reachability after next initialization:
6000-1fe1-0000-0d60-0009-8080-0434-002e
via adapter: via fc nport: connected:
dga133.1001.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d64 No
dga133.1002.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d62 Yes
dga133.1003.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d63 No
dga133.1004.0.1.0 pga0.0.0.1.0 5000-1fe1-0000-0d61 Yes
dgb133.1001.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d64 No
dgb133.1002.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d62 Yes
dgb133.1003.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d63 No
dgb133.1004.0.2.0 pgb0.0.0.2.0 5000-1fe1-0000-0d61 Yes
6000-1fe1-0000-0d60-0009-8080-0434-002f
6–64 Using Fibre Channel Storage