Technical data
Press Enter to display the first submenu in the Operation Menu, Switch
Offline:
Operation Menu:
Switch Offline
8. Press the down button until the Reboot submenu item is displayed:
Operation Menu:
Reboot
9. Press Enter. You can change your mind and not reboot:
Reboot
Accept? Yes No
10. Use the Tab/Esc button to select Yes. Press Enter to reboot the switch
and execute the POST tests.
____________________ Note _____________________
After changing any configuration menu settings, you must
reboot the switch for the change to take effect.
Refer to the switch documentation for information on other switch
configuration settings.
6.8.1.2.3 Setting the DS-DSGGB-AA and DS-DSGGC-AA/AB Ethernet IP Address
and Subnet Mask from a PC or Terminal
For the DS-DSGGB-AA and DS-DSGGC-AA/AB switches, which do not have
a front panel, you must use a connection to a Windows 95/98/NT/2000 PC or
video terminal to set the Ethernet IP address and subnet mask.
To set the Ethernet IP address and subnet mask for the DS-DSGGB-AA or
DS-DSGGC-AA/AB switches, follow these steps:
1. Connect the switch serial port to a terminal or PC COM port with a
standard serial cable with a DB9 connector. Note that the serial port is
only used for initial power-on self-test (POST) verification, IP address
configuration, or for resetting the factory/default settings. Ensure that
you make the connection to the switch serial port and not the Ethernet
port.
2. If you are using a PC, start a remote communication program, for
example, HyperTerminal.
3. Set the port settings to 9600 bits per second, 8 bits per character, no
parity, 1 stop bit, and no flow control.
Using Fibre Channel Storage 6–31