Technical data
Figure 6–11: A Simple Zoned Configuration
KGPSA
Memory
Channel
KGPSA
KGPSA
KGPSA
Fibre Channel Switch
Cluster 1
Member
System 1
Cluster 1
Member
System 2
Cluster 2
Member
System 2
Cluster 2
Member
System 1
02 46 81012 14
ZK-1709U-AI
Memory
Channel
Memory
Channel
Memory
Channel
HSG 80
Controller A
HSG 80
Controller B
RA8000/ESA12000
Port 1
Port 1
Port 2
Port 2
HSG 80
Controller A
HSG 80
Controller B
RA8000/ESA12000
Port 1
Port 1
Port 2
Port 2
13 5 7 9111315
For information on setting up zoning, see the SAN Switch Zoning
documentation that is provided with the switch.
6.6 Cascaded Switches
Multiple switches may be connected to each other to form a network of
switches, or cascaded switches.
A cascaded switch configuration, which allows for network failures up to and
including the switch without losing a data path to a SAN connected node,
is called a mesh or meshed fabric. Figure 6–12 shows an example meshed
fabric with three cascaded switches. This is not a no-single-point-of-failure
(NSPOF) configuration.
Using Fibre Channel Storage 6–21