Technical data

6. Install the CCMFB fiber-optic converter in slot opto only, 0/opto,
1/opto, 2/opto,or3/opto, as appropriate.
7. Install a BN39B-01 1-meter (3.3-foot) link cable between the CCMFB
optical converter and the CCMLB linecard.
8. Repeat steps 1 through 7 for each CCMFB module to be installed.
5.6 Running Memory Channel Diagnostics
After the Memory Channel adapters, hubs, link cables, fiber-optic converters,
and fiber-optic cables have been installed, power up the systems and run
the Memory Channel diagnostics.
There are two console level Memory Channel diagnostics, mc_diag and
mc_cable:
The mc_diag diagnostic:
Tests the Memory Channel adapters on the system running the
diagnostic.
Runs as part of the initialization sequence when the system is
powered up.
Runs on a standalone system or while connected to another system or
a hub with the link cable.
The mc_cable diagnostic:
Must be run on all systems in the cluster simultaneously (therefore,
all systems must be at the console prompt).
__________________ Caution __________________
If you attempt to run mc_cable on one cluster member
while other members of the cluster are up, you may crash
the cluster.
Is designed to isolate problems to the Memory Channel adapter,
BC12N or BN39B link cables, hub linecards, fiber-optic converters,
BN34R fiber-optic cable, and, to some extent, to the hub.
Indicates data flow through the Memory Channel by response
messages.
Runs continuously until terminated with Ctrl/C.
Reports differences in connection state, not errors.
Can be run in standard or virtual hub mode.