User guide
Table Of Contents
- MSA1000 User Guide
- Contents
- About this Guide
- Chapter 1: Introduction
- Chapter 2: Operating System Specific Information
- Chapter 3: MSA1000 Setup and Sample Configurations
- Chapter 4: Operation and Management
- Chapter 5: Array Configuration Utility (ACU)
- Installing the ACU on the Server
- Accessing the ACU
- Description of Screen Regions
- Configuring a New Controller
- Modifying an Existing Controller
- Probability of Logical Drive Failure
- Chapter 6: Command Line Interface (CLI)
- CLI Overview
- CLI Setup
- Help Commands
- Display Commands
- Array Controller Configuration Commands
- LUN Management Commands
- Server Connection Commands
- Selective Storage Presentation/Access Control List Commands
- Appendix A: Regulatory Compliance Notices
- Appendix B: Electrostatic Discharge
- Appendix C: Specifications
- Appendix D: Hard Drive Arrays
- Appendix E: Recovering from Hard Drive Failure
- Appendix F: Controller Display Messages
- Appendix G: Recovery ROM and ROM Cloning
- Appendix H: SCSI ID Assignments
- Index

Controller Display Messages
218 Modular SAN Array 1000 User Guide
202 ARRAY
CONTROLLER
OVERHEATING
Error The temperature sensor on
the array controller
indicates that the array
controller is starting to
exceed the normal
operating range.
Check all MSA1000 fans
and insure they are
operating. Any failed fans
should be replaced. Insure
that there are drive blank
cartridges in any empty
drive bays of the
MSA1000 chassis. If only
one array controller is
inserted, insure that there
are cover plates installed in
the empty array controller
bay and the fibre bay of
the MSA1000 chassis.
203 ARRAY
CONTROLLER
OVERHEATED
Error The temperature sensor on
the array controller
indicates that the array
controller has exceeded the
safe operating range.
The MSA1000 should be
powered off as soon as
possible to avoid hardware
failure.
Check all MSA1000 fans
and insure they are
operating. Any failed fans
should be replaced. Insure
that there are drive blank
cartridges in any empty
drive bays of the
MSA1000 chassis. If only
one array controller is
inserted, insure that there
are cover plates installed in
the empty array controller
bay and the fibre bay of
the MSA1000 chassis.
204 ARRAY
CONTROLLER
DISABLED
Error The array controller has
been disabled due to a
redundancy failure.
Remove the failed array
controller, wait 10 seconds,
and then reinsert the array
controller insuring that it is
fully seated in the chassis.
Should the issue persist
please contact HP support.
205 ARRAY
CONTROLLER
RESTARTING
Informational The array controller has
completed firmware
cloning and will be
restarted automatically.
Table 20: LCD Message Descriptions
Message Type Description Action