User guide
4-16 Compaq StorageWorks RAID Array 4100 User Guide
9. With the daughterboard installed, push the RA4000 Controller in as far
as it will go
.
10. Close both latches against the rear panel . The levers on each latch
should catch behind the metal lip, drawing the board into place and
securing it.
1
2
2
Figure 4-21. Replacing the RA4000 Controller
11. Replace the GBIC and reconnect the Fibre Channel cable.
12. If the system was powered down, power on the RA4100, and then
power on the attached servers.
Replacing GBICs
If a GBIC fails, follow this procedure to replace the failed GBIC. It is not
necessary to power down the system.
1. Remove the Fibre Channel cable from the back of the failed GBIC.
Replace the protective covers on the cable
.
2. Insert the dust plug covers into the GBIC module.
3. Squeeze the tabs on either side of the module or, if equipped with a
locking mechanism, flip the bail to the unlocked position.