User guide
Running the Array Configuration Utility 5-27
Error and Warning Messages
When you start the Array Configuration Utility, the software checks each
controller to detect errors in its configuration. If a problem is found, the Array
Configuration Utility displays an error or warning message that describes the
problem. Error and warning messages include instructions to correct
configurations. If a warning message indicates “Internal Error Has Occurred”
and cites an error code number, the problem requires assistance from Compaq
technical support. See the “About This Guide” section at the beginning of this
guide for technical support phone numbers.
NetWare Online Array Configuration
Utility (CPQONLIN)
The NetWare Online Array Configuration Utility, also called CPQONLIN, is
an NLM for configuring drive arrays without shutting down the server.
CPQONLIN also provides information about the status of drives attached to
the RA4000 controller. It indicates drive failure, expansion, or waiting for
expansion or rebuild (queued). Before loading CPQONLIN.NLM, you must
load the appropriate device drivers
CPQFC.HAM and CPQSHD.CDM.
CPQONLIN.NLM is located in the ONLINE directory of Novell SSD Disk 4.