User`s guide

3-14 StorageWorks Fibre Channel Storage Switch Service Guide
SHR-1217
2
0
2
4
6
8
10
12
14
1
2
Figure 3-9. Main Chassis Fans with Sub-assembly and Power Connections
4. Carefully unplug the two chassis fan power connectors (Figure 3-9, item
2) from the motherboard and lift the sub-assembly from the chassis,
then remove the failed fan.
Installing a Fan Assembly
NOTE:
When reconnecting he fan power, ensure that the connection is properly oriented.
Do not force the connection.
To install a fan assembly:
1. Position the fan sub-assembly with enough space to connect both fan
power connectors to the motherboard.
2. Position the subassembly on the chassis rear panel over the screw holes.
3. Secure the subassembly to the chassis using four screws.
4. Carefully plug the two chassis fan power connectors (Figure 3-9, item 2
) into the motherboard.