User`s guide

Troubleshooting 2-27
Table 2-3
Error Messages by Firmware Module
continued
Module Error Severity Explanation Action
SPFCOST (3) An error occurred with
computing the multicast path
tree.
Run the LSDbAllShow
command. Contact
Customer Support.
NBFSM NGBRSTAT E (2)
An error occurred in the
neighbor Finite State
Check the neighbor’s state
with the nbrStateShow
command.
If the state is not
NB_ST_FULL, force a state
change with the portDisable
command followed by
portEnable.
After a few seconds, if the
state is not NB_ST_FULL,
reboot both the local and
remote Switches.
UCAST ADDPATH (1)
A static path configuration
failed.
Check command
parameters.
RELICPDB (2)
The path selection task
received an E_Port SCN, but
the port was already ISL.
Run the ucastAllShow
command. Contact
customer support.
SPFCOST(3 )
An error occurred with
computing the unicast path
tree.
Run the LSDAllShow
command. Contact
customer support.
MQ QREAD (1) A task was unable to receive
a message.
Run the command
show<queue ID> with the
ID of the queue reported in
the error. Contact customer
support.
QWRITE (1) A task was not able to post a
message on a queue.
See MQ-QWRITE Error on
page -7 for more
information.
SYS NOMEM (1)
The system’s memory is
exhausted.
Reboot the Switch. Contact
customer support.
continued