User`s guide
2-24 StorageWorks Fibre Channel Storage Switch Sevice Guide
Feb 12 08:48:29
0000DIAG-PORTSTOPPED, 1
0Port N no longer transmitting, ftx counter stuck
at nnnn
Error Messages by Firmware Module
Table 2-3 shows the error messages organized by firmware module.
Table 2-3
Error Messages by Firmware Module
Module Error Severity Explanation Action
Flood INVLSR (3)
An unknown Link State
Record has been received
from a neighbor Switch.
Check that all paths and
routing tables are correct
using the commands
uPathShow <domain>, or
uPathAllShow.
If the paths are not correct
reboot the neighbor Switch
that sent the wrong data.
Check the paths and routes
again. If they are still
incorrect, reboot the local
Switch.
LSRLEN (2)
The local Switch is trying to
create a Link State Update
that exceeds the maximum
length.
Check that all paths and
routing tables are correct. If
they are not, reboot the local
Switch.
FSPF BADSRC (3)
The neighbor Switch domain
ID has changed, without the
link going down.
The system automatically
recovers.
continued