2-20 StorageWorks Fibre Channel Storage Switch Sevice Guide
Probable cause: Failure of Interface module
Action: Replace Interface module
Probable cause: Failure of G_Port or FL_Port ASIC
Action: Replace Interface module
Cross Port Test Error Messages
The cross port test is initiated by issuing the crossPortTest nFrames
command through Telnet where, nFrames is the number of frames to run.
See crossPortTest for more information.
If the test does not
find an error, there is no output through Telnet. One of
the following register names is displayed
in the sample error messages.
Replaces the variable
regname
, as follows:
■
Enc_in
– Encoding error, inside frame
■
CRC_err
– Cyclic redundancy check on frame failed
■
TruncFrm
– Truncated frame
■
FrmTooLon
g – Frame too long
■
BadEOF
– Bad end of file
■
Enc_out
– Encoding error, outside frame
■
BadOrdSet
– Bad symbol on fiber optic cable
■
DiscC3
– Discarded Class 3 frames.
Feb 12 08:48:29
0000DIAG-ERRSTAT, 1, spinSilk: pass nn
00Port N regname error counter is nnnn sb 0
Probable cause:
Failure of fiber cable
Action:
Replace fiber cable
Probable cause:
Failure of GBIC module
Action:
Replace GBIC module
Probable cause:
Failure of G_Port or FL_Port ASIC