User`s guide

Troubleshooting 2-9
Port Register Test
Pressing <Enter> while Port Register Test is selected displays a reminder to
take the Switch offline if it is not offline. If the message is displayed, take the
Switch offline as described in Switch Offline.
Pressing <Enter> starts the test, which checks the Switch’s G_Port and
FL_Port ASIC registers. The ports tested are 0 to 16 including the G_Port and
FL_Port ASIC for each port, plus the G_Port and FL_Port ASIC for Switch’s
internal port.
If the port register is all right, the panel displays:
Port Reg Test
Reg Test OK
RDRAM Test
This test checks the memory on the FL_Port interface cards. Pressing <Enter>
while rdram Test is selected displays a reminder to take the Switch offline,
if it is not offline. If the message is displayed, take the Switch offline as
described in section Switch Offline.
If the Switch passes the test:
Rdram Test: Passed
Central Memory Test
Pressing <Enter> with Central Memory Test selected displays a reminder to
take the Switch offline. If the message is displayed, take the Switch offline as
described in section Switch Offline.
If the Switch passes the test:
Central Memory Test: Passed