User guide

StatusInternal health LED
color
HP Systems Insight
Display LED and color
One or more of the following conditions may exist:RedPPM failure, slot X
(amber)
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding processor is
installed.
FBDIMM in slot X has failed.RedFBDIMM failure, slot X
(amber)
FBDIMM in slot X is in a pre-failure condition.Amber
One or more FBDIMMs has failed. Test each bank of FBDIMMs by
removing all other FBDIMMs. Isolate the failed FBDIMM by replacing
each FBDIMM in a bank with a known working FBDIMM.
RedFBDIMM failure, all
slots in one bank
(amber)
Bank X failed over to the online spare memory bank.AmberOnline spare memory
(amber)
Invalid online spare memory configuration.RedOnline spare memory
(flashing amber)
Online spare memory enabled and not failed.GreenOnline spare memory
(green)
Bank X failed over to the mirrored memory bank.AmberMirrored memory
(amber)
Invalid mirrored memory configuration.RedMirrored memory
(flashing amber)
Mirrored memory enabled and not failed.GreenMirrored memory
(green)
The Health Driver has detected a cautionary temperature level.AmberOvertemperature
(amber)
The server has detected a hardware critical temperature level.Red
PCI riser cage is not seated.RedRiser interlock (amber)
One fan is failed or removed.AmberFan module (amber)
Two or more fans have failed or are removed.Red
Hard Drive LEDs
DescriptionItem
Fault/UID LED (amber/blue)1
Online LED (green)2
VLS12000 Node Components, LEDs, and Buttons 149