QuickSpecs
VMware
VMwareVMware
VMware
ESX Server 2.5.3, 2.5.4 and 3.0.1
-MSCS Clustering
**
Windows 2000
Advanced Server
Windows Server
2003
Enterprise Edition
MPIO for VMware,
Native in OS
*Follows initial release, check posted Operating Specific Release Notes or software documentation
**For more detailed information on Cluster Server Support see the VMware Release Notes
http://h18006.www1.hp.com/products/storageworks/eva8000/index.html
***For Disaster Tolerance configurations in the EVA/Windows 2003 environment, please refer to the HP Cluster Extension EVA
QuickSpecs:
http://www.hp.com/go/clxeva
****For Disaster Tolerance configurations in the EVA/RedHat EL 4 or SUSE/SLES 9 or 10 environments, please refer to the HP
Cluster Extension EVA QuickSpecs:
http://www.hp.com/go/clxeva
*****
**********
*****
Support on EVA4000 only. For information on the specific Microsoft Windows XP configuration support see the SAN Design
Guide:
http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=SupportManual&lang=en&cc
=us&docIndexId=179111&taskId=101&prodTypeId=12169&prodSeriesId=470490
Cabinet Density
Cabinet DensityCabinet Density
Cabinet Density
A single 42U EVA cabinet can house up to 84.0 TB of raw capacity (using 500 GB FATA disks).
NOTE:
NOTE:NOTE:
NOTE:
Maximum cabinet capacity will vary based available upon U space. The total number of
controllers, enclosures supported and other devices. For example, the Rack System/E when fully
configured with an EVA8000 support a maximum of 11 enclosures.
Racking Guidelines and
Racking Guidelines andRacking Guidelines and
Racking Guidelines and
Power Distribution
Power DistributionPower Distribution
Power Distribution
Distribution Units (PDUs) according to the voltage used in the country the solution is ordered. These
PDUs provide redundant power and are located in the bottom and back of the cabinet for power cable
entrance by the floor. The PDUs are 220/240V. The 220/240V PDUs are 0U high with a total of two AC
power cords extending outside the cabinet.
For the EVA4100 Starter Kits, EVA4100, EVA6100 and EVA8100 a variety of HP 10000 G2 Series Rack
offerings and integration options are available. The EVA configurator tools utilize a 42U HP 10000 G2
Series Rack as the standard recommendation and will provide a 220/240V PDU and country specific
power cords. The EVA4100 Starter Kits and EVA4100/6100/8100 configurations can be customized to
meet a wide variety of customer needs. Both the height and types of rack and PDUs can be modified
based upon the specific customer need. If other devices, such as servers, switches or back-up devices,
are to be installed with the EVA; this can be specified and the cabinets and PDUs can be modified to
support the configuration. The EVA4100 Starter Kits and EVA4100/6100 also support 36U racks and
100V PDU (Supported in Japan).
For more information on configuration and PDU support for the 10000 G2 Series Rack please see the
following URL:
http://h18004.www1.hp.com/products/servers/proliantstorage/racks/10000g2series.html
The EVA also supports the 5642 (42U) Rack Cabinet System as a field installed option.
NOTE:
NOTE: NOTE:
NOTE:
When adding additional devices to existing racks ensure that the installed PDUs will support the
new power requirements.
QuickSpecs
HP StorageWorks Enterprise Virtual Array Family
HP StorageWorks Enterprise Virtual Array FamilyHP StorageWorks Enterprise Virtual Array Family
HP StorageWorks Enterprise Virtual Array Family
Product Highlights
DA - 12745 Worldwide — Version 2 — November 12, 2007