QuickSpecs
The M5314C FC drive enclosure has dual redundant hot plug FC I/O modules that allow the controllers
to distribute I/Os between the two modules and provides redundant paths should either FC I/O module
become unavailable. The enclosure also has dual redundant hot plug power supplies and dual hot plug
blowers. The enclosure also has a hot plug Environmental Monitoring Unit (EMU) to monitor and report
the condition of the power supplies and fans. The EMU can be replaced without affecting I/O operations.
The FC and FATA disk drives have dual FC ports which can be redundantly accessed by each controller.
The drives are hot plug. The drives can be arranged, using redundant Vraid1 or Vraid5 protection, so
that a drive failure will not cause loss of data. Optional virtual sparing can be configured so that a drive
failure will trigger an automatic rebuild of the Vraid1 or Vraid5 protection using the virtual spare.
All EVAs have dual redundant power distribution. Two independent power cords distribute power through
two Power Distribution Units (PDUs) to each side of the EVA cabinets and to each power supply of the
controllers and to each power supply of the drive enclosures and to each of the FC loop switches. Each
cabinet power cord can be connected to independent power sources. For maximum availability, a
customer should provide redundant power from independent power circuit breakers, independent power
lines from the power company and even independent power companies.
Integration
IntegrationIntegration
Integration
HP EVA4100 Starter Kits and EVA4100/6100/8100 models are 4Gb/s FC Switched Fabric "enabled"
and can operate on 4Gb/s or 2Gb/s FC Switched Fabric SANs. They can co-exist in the same FC SAN
with EVA3000 and EVA5000 FC storage solutions and many other SAN devices.
Manageability
ManageabilityManageability
Manageability
HP StorageWorks Command View EVA provides the capability to manage the EVA Array family in a SAN
or direct connect Fibre Channel host attach configuration. HP Command View EVA software runs on a
variety of server configurations; ProLiant DL380 G5 and DL585 G2 Storage Servers are the perfect
platforms from which to run Command View EVA. ProLiant Storage Server gateway models (including the
DL380 G5 x64 SAN Storage Server and DL585 G2 Storage Server) allow you to stretch your investment
by combining EVA management, file and print services, and iSCSI connectivity all on the same platform.
The powerful Command View EVA provides an easy mechanism to manage up to 16 EVA units in a SAN
configuration. Industry leading security enhancements in Command View now allows administrators to
take advantage of Windows domains and local groups. Command View integrates with Windows Active
Directory to authorize and authenticate users. In addition, all user actions and events that change system
state are logged. Administrators can now use the audit logging capabilities to see who did what and
when.
The Command View EVA media kits and license are required with all EVA models. HP Command View
EVA requires a License to use (LTUs) equal to, or greater than the total raw capacity of each array. For
the HP EVA4100 Starter Kits, Command View EVA software is included as well as licensing for up to 4
TBs as part of the bundled offering.
NOTE:
NOTE: NOTE:
NOTE:
HP Command View EVA software and up to 4-1 TB License to Use (LTU) are included in the
EVA4100 Starter Kits.
QuickSpecs
HP StorageWorks Enterprise Virtual Array Family
HP StorageWorks Enterprise Virtual Array FamilyHP StorageWorks Enterprise Virtual Array Family
HP StorageWorks Enterprise Virtual Array Family
Product Highlights
DA - 12745 Worldwide — Version 2 — November 12, 2007
Page 16