Technical data

Replacing the SC
SI I/O module
CAUTION:
The SCSI I/O module with an integrated EMU is not hot-pluggable. Before replacing the module, all I/O
from the servers must be stopped and the MSA must be powered down.
Before you begin
CAUTION:
Before removing a component or blanking panel from an operational device, make sure that you
have the replacement part available. Removing a component or blank impacts the airow and
cooling ability of the device. To avoid possible overheating, insert the new or replacement component
withinoneortwominutes. Iftheinternaltemperatureexceedsacceptablelimits,thedevicemay
overheat and automatically shut down or restart.
Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
Before replacing the SCSI I/O module:
Verify that the module status LED is not illuminated or is ashing amber.
Check the array controller LCD display panel for error messages and take appropriate action.
Removing the component
1. Review al
l warnings, cautions, and preparation procedures as detailed in Warnings and precautions.
NOTE:
Before re
moving the SCSI I/O module, label all cables. This ensures their reconnection in
the corr
ect conguration.
2. Disconnect all SCSI cables from the SCSI I/O module.
3. PressdownontheSCSII/Omodulelatch(1)andpulltheSCSII/Omoduleoutoftheenclosure(2).
2
1
1 5 559
90
Customer replaceable components