Technical data
Message Type
Description Action
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
Informational
A SCSI hard drive may be
close to failing. This was
determined either by the
hard drive firmware itself
using SMART technology or
by the array controller using
monitor and performance
testing.
The hard drive should
be replaced as soon as
possible.
82 DRIVE HOT A
DDED
BOX #<n>, BA
Y <n>
Informational
ASCSIhardd
rive has
been added t
otheMSA
chassis or a
ttached external
storage en
closure.
83 DRIVE HOT
REMOVED BOX #<n>,
BAY <n>
Informational
A SCSI hard drive has been
removed from the MSA
chassis or attached external
storage enclosure.
84 DRIVE FAILURE
BOX #<n>, BAY <n>
Error
ASCSIharddriveinthe
MSA chassis or attached
external storage enclosure
has failed. If the hard drive
was part of a configured
volume, then the state of the
volume will depend on the
fault tolerance used.
The hard drive should
be replaced as soon as
possible.
85 BAD DRIVE
FRMWARE BOX #<n>,
BAY <n>
Error
ASCSIharddrivehas
been detected that has
known, bad firmware on it.
Continued use of this hard
drive could result in hard
drive failure, decreased
performance, or data loss.
Eithe
r the hard drive firmware
shoul
d be updated or
the ha
rd drive should
be re
placed as soon as
poss
ible.
86 DRIVE POSITION
CHANGE DETECTED
Informational
The SCSI hard drives that
make up a configured
volume have been
physically moved within
the MSA1000 chassis or
attached external storage
enclosure. The array
controller has updated its
configuration information
accordingly.
87 DRIVE POSITION
CHANGE INVALID
Informational
The SCSI hard drives that
make up a configured
volume have been
physicallymovedinsucha
way that the array controller
can no longer access the
configured volume.
The MSA should be powered
off and the hard drives
restored to their original
positions.
88 NON-COMPAQ DRIVE
BOX #<n>, BAY <n>
Informational
An unsupported hard
drive was located in the
indicated bay of the storage
enclosure.
46