Recovering from Hard Drive
Failure
Caution: Back up all data before removing drives or changing configurations.
Failure to do so could result in permanent loss of data. Before moving drives
and arrays, run the Array Configuration Utility.
The purpose of fault-tolerant configurations on the MSA1000 Controller is to
protect against data loss due to drive failure. Although the MSA1000 Controller
firmware is designed to protect against normal drive failure, it is imperative that
you perform the correct actions to recover from a drive failure without
inadvertently inducing any additional drive failures. Multiple drive failures in the
same array generally result in data loss (exceptions include failures following
activation of a spare drive, and failure of drives in a mirroring configuration that
are not mirrored to one another or Advanced Data Guarding configuration).
Drives may be either Ultra2, Ultra3, or Ultra320 Pluggable Universal Hard Disk
Drives. Drives that are to be grouped in the same array should be of the same
capacity. The excess capacity of a larger drive cannot be used by the array and will
be wasted.