Specifications

Operation and Management
50 MSA1000 Reference Guide
To remove the blower from the power supply:
1. Push in on the two port wine-colored blower tabs 1 while pulling on the
blower element 2. See Figure 16 for an illustration.
Figure 16: Replacing the blower
Caution: Pressing on the center section of the blower can damage the blades.
To prevent this, press only on the outer edge of the blower.
2. Align the new blower’s guidepost 2 with the power supply connector 1.
Slide the replacement blower into the blower base 4 until the tabs 3 snap into
place.
See Figure 17 for an illustration.
1
1
2