Specifications

Physical and Operating Specifications 78
Table 11 Hardware specifications
Item Components
Status LED indicators
Front panel
System board
Power/system health status
UID status
NIC activity
LAN activity
LAN link status
Power/system health status
UID status
Auxiliary power indicators
Power supply unit (PSU) 750 W, redundant PSU support
Thermal solution Four 80mm system fans
Table 12 Physical dimensions
Item
Description
System board dimension 17.935’’x6.5’’
Server dimensions
Rack
448W X87.5H X 735.5D (mm)
Server weight, basic configuration
(excluding keyboard and monitor)
20 kg
Table 13 Environmental specifications
Item
Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35° (+50 to +95°F)
-30 to 60° (-22 to 140°F)
-30 to 60° (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)