User guide

System BIOS configuration 38
Table 23 POST Error Messages
Error code Error message Description/corrective action
609h
Temperature Violation
Detected! Waiting 5
minutes for system to
cool. Press ESC Key
to resume booting
without waiting for the
system to cool.
Warning: Pressing
ESC is NOT
recommended as
system may shutdown
unexpectedly.
Recheck Temperature
in xxx seconds!
If system detects one or more temperature sensor over heat.
612h
Power Supply Failure
or Power Supply
Unplugged
When two powers supply installed, if one of the power cable is not
connected or one of the power is failed, this will appear.
611h System Event Log full If system can not store any more event log, this will appear at post.
615h
System Fan 1 missing!
The cooling solution is
not redundant due to
a detected fan failure.
If only system fan1 is not installed or failed, system will announce this
message and press F1 continue to boot
616h
System Fan 2 missing!
The cooling solution is
not redundant due to
a detected fan failure.
If only system fan2 is not installed or failed, system will announce this
message and press F1 continue to boot
617h
System Fan 3 missing!
The cooling solution is
not redundant due to
a detected fan failure.
If only system fan3 is not installed or failed, system will announce this
message and press F1 continue to boot
618h
System Fan 4 missing!
The cooling solution is
not redundant due to
a detected fan failure.
If only system fan4 is not installed or failed, system will announce this
message and press F1 continue to boot
POST-related troubleshooting
Refer to HP ProLiant SL170z Maintenance and Service Guide for troubleshooting guidelines.