Specifications
3-40  Compaq ProLiant ML350 Maintenance and Service Guide 
100 – 199, Primary Processor Test Error Codes 
The 100 series of diagnostic error codes identifies failures with processor and system board 
functions. 
Table 3-3 
Primary Processor Test Error Codes 
Error Code  Description  Recommended Action 
101-xx  CPU test failed.  1.  Replace the failed processor and retest. 
2.  Replace the system board and retest. 
103-xx  DMA page registers test failed. 
104-xx  Interrupt controller master test 
failed. 
105-xx  Port 61 error. 
106-xx  Keyboard controller self-test 
failed. 
Replace the system board and retest. 
107-xx  CMOS RAM test failed. 
108-xx  CMOS interrupt test failed. 
109-xx  CMOS clock load data test failed. 
1.  Replace the battery/clock module and retest. 
2.  Replace the system board and retest. 
110-xx  Programmable timer load data test 
failed. 
111-xx  Refresh detect test failed. 
112-xx  Speed test slow mode out of 
range. 
113-xx  Protected mode test failed 
Replace the system board and retest. 
114-xx  Speaker test failed.  1.  Verify the speaker connection and retest. 
2.  Replace the system board and retest. 
116-xx  Cache test failed.  Replace the processor and retest. 
122-xx  Multiprocessor dispatch test 
failed. 
123-xx  Interprocessor communication test 
failed. 
1.  Check the system configuration and retest. 
2.  Replace the processor board and retest. 
3.  Replace the system board and retest. 
199-xx  Installed devices test failed.  1.  Check the system configuration and retest. 
2.  Verify cable connections and retest. 
3.  Check switch and/or jumper settings and retest. 
4.  Run the Configuration Utility and retest. 
5.  Replace the processor board and retest. 
6.  Replace the system board and retest. 