Specifications

3-36 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1792-Secondary
Disk Controller
Failure
None Part of the IDE drive
electronics has
failed.
Run Diagnostics and replace failed
assembly as indicated.
1793-Secondary
Controller or Disk
Failure
None The IDE controller or
an attached drive
has failed.
Run Diagnostics and replace failed
assembly as indicated.
1793-Drive Array
Array Accelerator
Battery Depleted
Data Lost.
(Error message
1794 also
displays.)
None Indicates that while
the system was in
use, power was
interrupted while data
was in the array
accelerator memory.
Array accelerator
batteries failed. Data
in array accelerator
has been lost.
Power was not restored within 8 to 10
days. Perform orderly system shutdowns
to avoid data remaining in the array
accelerator.
1794-Drive Array
Array Accelerator
Battery Charge
Low.
Array Accelerator is
temporarily
disabled.
Array Accelerator
will be re-enabled
when battery
reaches full
charge.
None Warning that the
battery charge is
below 75%. Posted
writes are disabled.
Replace the array accelerator board if
batteries do not recharge within
36 power-on hours.
1795-Drive Array
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily
disabled.
None Indicates that while
the system was in
use, power was
interrupted while data
was in the array
accelerator memory.
Data stored in the
array accelerator does
not correspond to this
drive array.
Match the array accelerator to the
correct drive array, or run the server
setup utility to clear the data in the array
accelerator.
continued