Specifications
3-36  Compaq ProLiant ML350 Maintenance and Service Guide 
Table 3-2 
POST Error Messages 
continued 
Error Code  Audible Beeps  Probable Source of 
Problem 
Action 
1792-Secondary 
Disk Controller 
Failure 
None  Part of the IDE drive 
electronics has 
failed. 
Run Diagnostics and replace failed 
assembly as indicated. 
1793-Secondary 
Controller or Disk 
Failure 
None  The IDE controller or 
an attached drive 
has failed. 
Run Diagnostics and replace failed 
assembly as indicated. 
1793-Drive Array – 
Array Accelerator 
Battery Depleted – 
Data Lost. 
(Error message 
1794 also 
displays.) 
None  Indicates that while 
the system was in 
use, power was 
interrupted while data 
was in the array 
accelerator memory. 
Array accelerator 
batteries failed. Data 
in array accelerator 
has been lost. 
Power was not restored within 8 to 10 
days. Perform orderly system shutdowns 
to avoid data remaining in the array 
accelerator. 
1794-Drive Array – 
Array Accelerator 
Battery Charge 
Low. 
Array Accelerator is 
temporarily 
disabled. 
Array Accelerator 
will be re-enabled 
when battery 
reaches full 
charge. 
None  Warning that the 
battery charge is 
below 75%. Posted 
writes are disabled. 
Replace the array accelerator board if 
batteries do not recharge within 
36 power-on hours. 
1795-Drive Array – 
Array Accelerator 
Configuration Error. 
Data does not 
correspond to this 
drive array. Array 
Accelerator is 
temporarily 
disabled. 
None  Indicates that while 
the system was in 
use, power was 
interrupted while data 
was in the array 
accelerator memory. 
Data stored in the 
array accelerator does 
not correspond to this 
drive array. 
Match the array accelerator to the 
correct drive array, or run the server 
setup utility to clear the data in the array 
accelerator. 
continued 