Specifications

3-32 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source
of Problem
Action
1785-Slot X Drive
Array not Configured
(followed by one of
the following):
None Drive array
configuration not
detected.
Run Compaq Array
Configuration Utility
(ACU)
Run the Array Configuration Utility (ACU).
No drives detected Power down the system and check SCSI
cable connections to make sure drives
are attached properly.
Drive positions appear
to have changed
Run Drive Array
Advanced Diagnostics
if previous positions
are unknown. Then
turn system power
OFF and move drives
to their original
positions.
Run Array Diagnostic Utility if previous
positions are unknown. Then power
down the system and move drives to
their original positions.
Configuration
information indicates
drive positions beyond
the capability of this
controller. This may
be due to drive
movement from a
controller that
supports more drives
than the current
controller.
To avoid data loss, power down the
system and reattach drives to the
original controller.
Configuration
information indicates
drives were
configured on a
controller with a
newer firmware
version.
To avoid data loss, reattach drives to the
original controller or upgrade the
controller firmware to the version on the
original controller using the Option
ROMPaq Utility.
(RESUME = F1 KEY)
Select F1 to resume.
continued