Specifications

3-30 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1778-Drive Array
resuming
Automatic Data
Recovery process
None This message
displays whenever a
controller reset or
power cycle occurs
while Automatic Data
Recovery is in
progress.
No action necessary.
1779-Slot X Drive
Array
Replacement
drive(s) detected
OR previously
failed drive(s) now
operational:
Port Y: SCSI ID Z:
Restore data from
backup if
replacement
drive X has been
installed.
None Intermittent drive
failure and/or possible
loss of data detected.
If this message displays and drive X has
not been replaced, this indicates an
intermittent drive failure. This message
also displays immediately following drive
replacement whenever data must be
restored from backup.
1780-Disk 0
Failure
None Hard drive/format
error detected.
Run Diagnostics. Replace failed
assembly as indicated.
1781-Disk 1
Failure
None Hard drive/format
error detected.
Run Diagnostics. Replace failed
assembly as indicated.
continued