Specifications

Diagnostics and Troubleshooting 3-29
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1777-Slot X Drive
Array ProLiant
Drive Storage
Enclosure Problem
Detected (followed
by one or more of
the following):
SCSI Port Y:
Cooling Fan
Malfunction
Detected
SCSI Port Y:
Overheated
Condition Detected
SCSI Port Y:
Side-Panel must be
Closed to Prevent
Overheating
SCSI Port Y:
Redundant Power
Supply Malfunction
Detected
SCSI Port Y: Wide
SCSI Transfer
Failed
SCSI Port Y:
Interrupt Signal
Inoperative
(RESUME = F1
KEY)
None Temperature violation
detected.
Check cooling fan operation by
placing hand over fan. Verify internal
plenum cooling fan in tower servers
or storage systems is operational. If
fan is not operating, check for
obstructions and verify all internal
connections. Replace unit side panel
if removed.
If the ProLiant Storage System
power LED is amber instead of
green, this indicates a redundant
power supply failure.
Check SCSI cables. If the message
indicates to check SCSI cables,
verify your cabling against the
diagrams in your Compaq Smart
Array Controller user guide. If the
routing is correct, replace cables on
the specified port until the POST
message is eliminated.
continued