Specifications
Diagnostics and Troubleshooting  3-29 
Table 3-2 
POST Error Messages 
continued 
Error Code  Audible Beeps  Probable Source of 
Problem 
Action 
1777-Slot X Drive 
Array – ProLiant 
Drive Storage 
Enclosure Problem 
Detected (followed 
by one or more of 
the following): 
SCSI Port Y: 
Cooling Fan 
Malfunction 
Detected 
SCSI Port Y: 
Overheated 
Condition Detected 
SCSI Port Y: 
Side-Panel must be 
Closed to Prevent 
Overheating 
SCSI Port Y: 
Redundant Power 
Supply Malfunction 
Detected 
SCSI Port Y: Wide 
SCSI Transfer 
Failed 
SCSI Port Y: 
Interrupt Signal 
Inoperative 
(RESUME = F1 
KEY) 
None Temperature violation 
detected. 
■  Check cooling fan operation by 
placing hand over fan. Verify internal 
plenum cooling fan in tower servers 
or storage systems is operational. If 
fan is not operating, check for 
obstructions and verify all internal 
connections. Replace unit side panel 
if removed. 
■  If the ProLiant Storage System 
power LED is amber instead of 
green, this indicates a redundant 
power supply failure. 
■  Check SCSI cables. If the message 
indicates to check SCSI cables, 
verify your cabling against the 
diagrams in your Compaq Smart 
Array Controller user guide. If the 
routing is correct, replace cables on 
the specified port until the POST 
message is eliminated. 
continued 