Specifications

Diagnostics and Troubleshooting 3-27
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1771-Primary Disk
Port Address
Assignment
Conflict
None Internal and external
hard drive controllers
are both assigned to
the primary address.
Run the server setup utility and correct.
1772-Secondary
Disk Port Address
Assignment
Conflict
None Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the server setup utility and correct.
1773-Primary
Fixed Disk Port
Assignment
Conflict
None Hard drive error
detected.
Run the server setup utility and correct.
1774-Slot X Drive
Array Obsolete
data found in Array
Accelerator. Select
F1 to discard
contents of Array
Accelerator. Select
F2 to write
contents of Array
Accelerator to
drives.
None SMART-2 Controller
error detected.
Data found in array accelerator is older
than data found on drives. Press F1 to
discard the older data in the array
accelerator and retain the newer data on
the drives.
continued