Specifications
3-26 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1767-Slot X Drive Array Option ROM is Not Programmed Correctly or
may Conflict with the Memory Address Range of an ISA Card. Check
the Memory Address Configuration of installed ISA Card(s) or run
Options ROMPaq Utility to attempt SMART-2/E Option ROM
Reprogramming.
Remove or reconfigure conflicting ISA
cards, especially any cards that are not
recognized by the server setup utility. Try
reprogramming the SMART-2/E
Controller ROM using the latest Options
ROMPaq Utility (version 2.29 or higher).
1768-Slot X Drive
Array – Resuming
logical drive
expansion process
None SMART-2 Controller
error detected.
No action required. This message
displays whenever a controller reset or
power cycle occurs while array
expansion is in progress.
1769-Slot X Drive
Array – Drive(s)
disabled due to failure
during expand. Select
F1 to continue with
logical drives
disabled. Select F2 to
accept data loss and
to re-enable logical
drives.
None SMART-2 Controller
error detected.
Data has been lost while expanding the
array; therefore, the drives have been
temporarily disabled. Press F2 to accept
the data loss and re-enable the logical
drives. Restore data from backup.
1770-Slot X Drive
Array – Critical Drive
Firmware Problem
Detected – Please
upgrade firmware on
the following drive(s)
using Options
ROMPaq (available
from
www.compaq.com):
SCSI Port Y SCSI ID Z
(RESUME = F1 OR
F2 KEY)
None Firmware update
need indicated.
The indicated drives are running
firmware that is known to cause
intermittent problems. Use the Options
ROMPaq Utility to upgrade firmware on
all drives to the latest revision.
Acquire from the Compaq website:
http://www.compaq.com/support
continued