Specifications

Diagnostics and Troubleshooting 3-23
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1724-Slot X Drive
Array Physical
Drive Position
Change(s) Detected
Logical drive
configuration has
automatically been
updated.
RESUME = F1 KEY
None Drive change
detected.
The logical drive configuration has been
updated automatically following physical
drive position changes. Press F1 to
resume.
1726-Slot X Drive
Array Array
Accelerator
Memory Size
Change Detected.
Array Accelerator
configuration has
automatically been
updated.
None Configuration
updated.
The array accelerator configuration has
been updated automatically due to
replacement of the array accelerator (or
controller), with one having different
cache memory size. Press F1 to resume.
1727-Slot X Drive
Array New
Logical Drive(s)
Attachment
Detected. If more
than 32 logical
drives, this
message will be
followed by:
Auto-configuration
failed: Too many
logical drives.
None Additional drives
detected.
The controller has detected an additional
array of drives that was attached when
the power was off. The logical drive
configuration information has been
updated to add the new logical drives.
The maximum number of logical drives
supported is 32. Additional logical drives
will not be added to the configuration.
Press F1 to resume.
continued