Specifications
3-22 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1720-Slot X Drive
Array – S.M.A.R.T.
Hard Drive(s)
Detect Imminent
Failure SCSI: Port
Y: SCSI ID Z.
None Hard drive predictive
failure condition
detected.
The indicated drive has reported a
SMART predictive failure condition. It
may fail at some time in the future. If this
drive is part of a non-fault-tolerant
configuration, back up all data before
replacing the drive and restore all data
afterward. If this drive is part of a
fault-tolerant configuration, do not
replace this drive unless all other drives
in the array are online. Press F1 to
resume.
1721-Slot X Drive
Array – Drive
parameter tracking
predicts imminent
failure. The
following devices
should be replaced
when conditions
permit. Do not
replace drive
unless all other
drives in the array
are on-line! Back
up data before
replacing drive(s) if
using RAID 0.
None Monitor and
Performance
threshold exceeded
condition.
Replace the drive when it is reasonable
for you to do so. The drive has not failed,
but Compaq recommends you replace
the drive.
1721- SMART
SCSI Hard Drive
detects imminent
failure
None Indicated drive has
reported a SMART
predictive-failure
condition and may
fail at some time in
the future.
If this drive is part of a
non-fault-tolerant configuration, back
up all data before replacing the drive,
and restore all data afterward.
-Or-
If this drive is part of a fault-tolerant
configuration, do not replace this drive
unless all other drives in the array are
online.
Press F1 to resume.