Specifications

3-20 Compaq ProLiant ML350 Maintenance and Service Guide
Table 3-2
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
1613-Low System
Battery.
None Real-time clock
system battery is
running low on power.
Replace battery (or add external battery)
as soon as possible.
1615-Power supply
configuration error
None Your configuration
requires an additional
power supply. A
moving bar indicates
that the system is
waiting for another
power supply to be
installed.
Install the additional power supply.
1615-Power
Supply Failure,
Power Supply
Unplugged, or
Power Supply Fan
Failure in Bay X.
None Power supply has
failed.
Reseat power supply firmly.
-Or-
Replace power supply as soon as
possible.
1617-Fan
controller not
responding.
System halted.
2 short Fan controller failure
detected.
Check and replace failed controller
assembly.
1617-I/O Fan
controller not
responding.
System halted.
2 short I/O fan controller
failure detected.
Check and replace failed controller
assembly.
1617-CPU Fan
controller not
responding.
System halted.
2 short CPU fan controller
failure detected.
Check and replace failed controller
assembly.
1618-PCI slots
powered down.
Check PCI Hot-Plug
enabler
connectors.
None PCI Hot Plug enabler
is missing or failed.
Check and replace missing or failed
assembly.
continued